98
Chapter 5 CLI
❑
: Parameter
Parameter
Setting
Contents
1. Server power
❑
Power On
❑
graceful
shutdown and off
❑
graceful
shutdown and
power-cycle
❑
hard reset
❑
NMI
❑
Hard Power off
Sets Server Blade power supply.
When using, refer to "6.2 Points to Note about Remote
Power OFF and the Shutdown Function" (
• Power On
Turns the server on.
• graceful shutdown and off
Turns off power after shutting down the OS using the
ServerView agent operating on the Server Blade.
• graceful shutdown and power-cycle
Turns power on again after turning off power and
shutting down the OS using the ServerView agent
operating on the Server Blade.
• hard reset
Reboots the Server Blade.
• NMI
Do not normally select.
• Hard Power off
The Server Blade is forcibly turned OFF.
Important:
When using this function, it is necessary to make various settings to
Server Blades. For details, refer to "6.2 Points to Note about
Remote Power OFF and the Shutdown Function" (
select when performing operations for Server Blades that are not
supported because there is a fear that unexpected operations such
as ACPI shutdown or power off may occur.
Remarks:
When ordering power on after ordering Server Blade power off,
check the power has been turned off correctly.
2. Set Server Maximum Restart
Retries
❑
0
–
7
Sets how many times will be retried after OS start fails.
If set to 0, retry will not be performed.
3. Set Server Boot Mode
❑
normal
❑
pxe-lan-1
❑
pxe-lan-2
❑
pxe-lan-3
❑
pxe-lan-4
❑
pxe-lan-5
❑
pxe-lan-6
❑
add-in-pci-lan-1
❑
add-in-pci-lan-2
Sets the boot method for Server Blade OS boot.
• normal
Sets the boot order of Server Blade to the default
settings set in BIOS.
• pxe-lan-1
–
pxe-lan-6
Set the selected LAN port to the top priority of the
Server Blade boot order and change so that it boots in
Preboot eXecution Environment (PXE).
• add-in-pci-lan-1 / add-in-pci-lan-2
Set LAN port 1 or 2 installed in the expansion card
slot module to the top priority of the Server Blade boot
order and change so that it Preboot eXecution
Environment (PXE).
Note:
When installing expansion cards other than a LAN card, if "add-
inpci-lan-1" or "add-in-pci-lan-2" is selected the Server Blade will
stop in the middle of boot. If this happens, turn off the Server Blade,
change the boot mode and then turn the power on again.
Содержание BX600 S3
Страница 12: ...12 Chapter 1 About Management Blades...
Страница 22: ...22 Chapter 2 Installing and Removing Management Blades...
Страница 62: ...62 Chapter 4 Web UI...
Страница 142: ...142 System fan unit 10 28 36 82 T Telnet 64 Set 29 40 76 U User name 16 46 W Web UI 16 26...