87
PRIMERGY BX600 Management Blade Hardware Guide
●
3. System Fan (1_3_3)
Displays and sets the status of the system fan.
❑
: Parameter
Parameter
Setting
Contents
1. System Fans Table
-
Displays a table showing the fans installed in the chassis
and PSU.
"• 1. System Fans Table (1_3_3_1)" (p.88)
2. System Fans Live Time Table
-
Displays and sets the lifetime of the system fan.
"• System Fan (1_3_3_2)" (p.89)
3. Set System Fans Daily Test
Time
❑
<hh.mm>
❑
disable
Sets the time when system fans operation tests are
performed everyday.
• <hh:mm>
Time is set in "hours: minutes". Time should be set in a
24-hour clock format.
• disable
Does not perform an operation test.
4. Fan Test At Every Start-up
❑
enable
❑
disable
Sets whether system fans operation tests are performed
every time fan operations start.
System Fans Overall Status
-
Displays the overall status of the system fans.
Important:
System fan units are non-durable components
(
→
"BX600 S3 Blade Server System Unit
Hardware Guide").
Change settings after replacement.
6. All Rear Fans Unavailable
Reaction
❑
continue
❑
shutdown-and-
poweroff
Sets system fan operations if all the system fans cannot be
operated.
• continue
System operations are continued.
• shutdown-and-poweroff
Shutdown is ordered for the server and power is turned
off.
+------------------------------------------+
| |
+------------------------------------------+
System Fan page_1_3_3
(1) System Fans Table
(2) System Fans Live Time Table
(3) Set System Fans Daily Test Time : disable
(4) Fan Test At Every Start-up : disable
(-) System Fans Overall Status : ok
(6) All Rear Fans Unavailable Reaction : continue
Enter selection or type (0) to quit:
Содержание BX600 S3
Страница 12: ...12 Chapter 1 About Management Blades...
Страница 22: ...22 Chapter 2 Installing and Removing Management Blades...
Страница 62: ...62 Chapter 4 Web UI...
Страница 142: ...142 System fan unit 10 28 36 82 T Telnet 64 Set 29 40 76 U User name 16 46 W Web UI 16 26...