background image

22

Chapter 2 Installing and Removing Management Blades

Содержание BX600 S3

Страница 1: ...tall remove Management Blades to the chassis and default settings Chapter 3 Software This chapter explains the software that can be used in collaboration with Management Blades Chapter 4 Web UI This c...

Страница 2: ...maintenance or restoration and damages that occur as a result of the data loss for any reason except for items covered under warranty High Safety This product is designed developed and manufactured a...

Страница 3: ...ibed by their representative characters instead of their exact key face appearance as show below E g Ctrl key Enter key key etc The following indicate the pressing of several keys at once E g Ctrl F3...

Страница 4: ...en Shots and Figures Screen shots and figures are used as visual aids throughout this manual Windows screens and file names may vary depending on the OS software or configuration of the server used Fi...

Страница 5: ...lade PRIMERGY BX600 Switch Blade Switch Blade Network Blade Cisco Catalyst Blade Switch 3040 GbE Pass Thru Blade FC Switch Blade FC Pass Thru Blade Microsoft Windows Server 2008 Standard Windows Micro...

Страница 6: ...describes the Management Blade firmware version V1 62 or later Microsoft Windows and Windows Server are trademarks or registered trademarks of Microsoft Corporation in the United States and other coun...

Страница 7: ...ote During Management Blade Operations 21 Chapter 3 Software 3 1 Software 24 Chapter 4 Web UI 4 1 Accessing Web Interface 26 4 2 Web UI Menu 27 4 2 1 Start Screen 27 4 2 2 Settings Menu 28 4 2 3 Syste...

Страница 8: ...ction 132 5 4 4 Logout 135 5 4 5 Reboot 135 5 4 6 System Information Dump 136 Chapter 6 Technical Information Knowledgebase 6 1 Specifications 138 6 2 Points to Note about Remote Power OFF and the Shu...

Страница 9: ...9 Chapter 1 About Management Blades This chapter explains the system features and the component names of Management Blades 1 1 Features 10 1 2 Component Names and Functions 11...

Страница 10: ...ntrol the chassis on a network Chassis management The status of the various blades within the chassis Server Blade Storage Blade Network Blade Management Blade the PSU and the system fan unit can be m...

Страница 11: ...TX connector An unshielded twisted pair UTP cable is plugged in 6 LAN active LED Blinking Amber transmitting data Blinks uniformly when NIC diagnostic function of the Management Blade is used 7 LAN li...

Страница 12: ...12 Chapter 1 About Management Blades...

Страница 13: ...stalling and Removing Management Blades This chapter explains how to install remove Management Blades to the chassis and default settings 2 1 Before Starting 14 2 2 Installing and Removing 15 2 3 Defa...

Страница 14: ...to the chassis Preparations Before starting prepare the following Management Blade The server and manual for each optional component Management terminal PC etc It is necessary to have a normal environ...

Страница 15: ...refer to BX600 S3 Blade Server System Unit Hardware Guide For the Management Blades to monitor the chassis constantly blade system management starts approx 1 minute after the power cable of the chassi...

Страница 16: ...ngs Perform the necessary settings from among the following depending on the management tools and method of communication to be used When using Web UI or CLI via Telnet LAN Interface Settings p 16 Whe...

Страница 17: ...ithin the same network that has a different speed the performance of the LAN transfer function will deteriorate For example the speed of all the ports is matched to that of the slowest port when using...

Страница 18: ...e serial port on the Management Blade operating in master mode 2 Connect an RS 232C cross cable to the management terminal Connect the other end of the cable to the serial port on the management termi...

Страница 19: ...The Account page of the User name root appears 4 Enter the following parameter and click Apply Password Enter a new password Confirm Password Enter the new password again Changing the password from CL...

Страница 20: ...is can be synchronized BX620 S4 Server Blade User s Guide Chapter 8 Hardware Configuration Utilities Management Blade time synchronization via the network Management Blade supports NTP as a time synch...

Страница 21: ...tions the Management Blade operating in master mode performs system management and operations The Management Blade operating in slave mode is continuously monitoring the master If an error occurs in t...

Страница 22: ...22 Chapter 2 Installing and Removing Management Blades...

Страница 23: ...23 Chapter 3 Software This chapter explains the software that can be used in collaboration with Management Blades 3 1 Software 24...

Страница 24: ...Guide and the ServerView User s Guide In order to use ServerView the following settings must be performed for Management Blade Connect the management terminal to which ServerView management console ha...

Страница 25: ...25 Chapter 4 Web UI This chapter explains the Web UI which enables the management and operation of the blade server system in the Management Blade 4 1 Accessing Web Interface 26 4 2 Web UI Menu 27...

Страница 26: ...e the Web browser and enter the following address in the address bar Enter the IP address of the Management Blade in IP address http IP address Port number default 80 when HTTP SSL is disable https IP...

Страница 27: ...as On the left side of the screen a setting menu containing various parameters is displayed like explorer and on the right the system setting page of the parameter selected in the menu is displayed Th...

Страница 28: ...s alarm handler Environment Maintenance This sets operations and monitors the status for the devices such as the chassis fan and PSU Also performs reboot settings for Management Blades Environment Mai...

Страница 29: ...tion regarding SNMP SNMP Interface p 42 SNMP Communities Sets the SNMP community name SNMP Trap Destination Sets the SNMP trap destination Console Redirection Performs settings related to console redi...

Страница 30: ...FC Switch Blade group Displays the information of installed Fibre Channel Switch Blade 4 2 8 FC Switch Blade Group p 51 Adv KVM Blade group when PG KVB102 is installed Displays the information and man...

Страница 31: ...e time and date when the Web page was accessed The following link appears in the both the header and footer areas Basic operations of the system settings page After entering characters or values into...

Страница 32: ...isplayed and past logs can be checked in order by clicking Next The remaining number of event logs can be checked in Free SEL entry number A maximum of 510 event log entries for Management Blade and 5...

Страница 33: ...s which have lower level of importance than the specified level can be set to not be sent Server Blade Power On Off Event Log Enable This is set whether power ON OFF and shutdown of the Server Blade i...

Страница 34: ...he PSU When using refer to 6 2 Points to Note about Remote Power OFF and the Shutdown Function p 139 power on turn on the main power of the chassis hard power off turn off the main power of the chassi...

Страница 35: ...ick Reset Expiry Date Displays the expiry date of the PSU dummy PSU Running time Displays the running time of the PSU dummy PSU Expiry Reporting Date Displays the date when Contact Check Box is checke...

Страница 36: ...tenance LEDs of the chassis are lit off the front and rear maintenance LEDs of the chassis are not lit blinking the front and rear maintenance LEDs of the chassis are blinking Rear Fan Door Status Rea...

Страница 37: ...and lifetime of the system fan unit Display Parameter Description ID Displays the numbers of each fan Status Displays the status of each fan Designation Displays the location of each fan Rear 1 2_1 2...

Страница 38: ...f the Management Blade is rebooted the main power supply and Server Blade power status is maintained If rebooted when the Management Blade is redundantly configured the master and slave are switched D...

Страница 39: ...net Protocol IP address subnet mask gateway and DHCP are set on the Internet Protocol page These settings become valid after rebooting the Management Blade Display Parameter Description Use DHCP Sets...

Страница 40: ...the port number of the HTTP interface Default value 80 Display Parameter Description Port Sets the port number of telnet Default value 3172 Drop Time Sets the amount of time secs until a hibernating...

Страница 41: ...me synchronization cannot be performed When NTP has been enabled always check whether the time synchronization is being performed in The Latest Sync Date Time Because straight after setting it sometim...

Страница 42: ...lications such as ServerView that perform communication using SNMP community names must be set Set a community name for which communication can be performed SNMP Trap Destination The adding and deleti...

Страница 43: ...click Apply IP Filter For Telnet IP Filter For HTTP IP Filter For SNMP IP filtering that permits connection is performed A maximum of 10 IP addresses can be registered IP addresses that permit connec...

Страница 44: ...the manufacture date of the FC Pass Thru Blade FC Pass Through Serial Number Displays the serial number of the FC Pass Thru Blade FC Pass Through Product Name Displays the product name of the FC Pass...

Страница 45: ...Description Name Sets the system name of the Management Blade to identify the device in SNMP Sets when using ServerView recommended Location Sets the location of the Management Blade in order to mana...

Страница 46: ...nnot be deleted Display Parameter Description Name Sets new user names Password Sets a password Passwords are case sensitive Confirm Password Sets again to confirm the password Permissions Sets the us...

Страница 47: ...ess 2 Displays the IP Address of LAN port 1 and LAN port 2 of the Server Blade Subnet Mask 1 Subnet Mask 2 Displays the subnet mask of LAN port 1 and LAN port 2 of the Server Blade Default Gateway 1 D...

Страница 48: ...the Management Blade of the master fails the slave will take over the management of the chassis Manufacture Displays the manufacturer Produce Date Displays the manufacture date Serial Number Displays...

Страница 49: ...Information Blade information Manufacture Displays the manufacturer Produce Date Displays the manufacture date Serial Number Displays the system serial number Product Name Displays the product name o...

Страница 50: ...for each GbE Pass Thru Blade Switch Blade Period polling This section is displayed only for Cisco Catalyst Blade Switch 3040 Determines whether or not to enable the regular settings confirmation to Ci...

Страница 51: ...Date Displays the manufacture date FC Switch Serial Number Displays the system serial number FC Switch Product Name Displays the product name FC Switch Product Number Displays the product number FC Sw...

Страница 52: ...g password in the Management Blade This setting does not set the password of the FC Switch Blade Reset Resets the FC Switch Blade Display Parameter Description Adv KVM blade Manufacture Displays the m...

Страница 53: ...ver Blade Adv KVM had been launched by user Date Time Displays the graphical console redirection has opened in the Date Time Reset Resets advanced KVM Module Display Parameter Description Image Name E...

Страница 54: ...a and set the connection of the remote floppy disk drives and CD DVD drives For details about using Virtual Media for floppy disk drive and CD DVD drive settings refer to the PRIMERGY BX600 S3 Blade S...

Страница 55: ...rverView agent If communication with ServerView agent does not begin during the timeout period Watchdog Time after the Server Blade POST exits an OS boot failure is detected and an action will be exec...

Страница 56: ...or floppy disks for activating hardware configuration tools is inside be sure to disable the OS Boot Monitoring function default settings are disable If you start up the system while the OS Boot Monit...

Страница 57: ...Description CMOS File Displays the CMOS settings file backed up to the Management Blade Slot number MAC address Backup date BIOS version is attached as the file name Select the settings file to be res...

Страница 58: ...E add in pci lan 1 add in pci lan 2 Sets LAN port 1 or 2 installed in the expansion card slot module to the top priority of the Server Blade boot order and change so that it boots in Preboot eXecution...

Страница 59: ...on function Used to identify the multiple Server Blades installed in the chassis blinking the Server Blade power LED is blinking off will not set the Server Blade power LED OS Type Displays the OS typ...

Страница 60: ...y Parameter Description No Displays the LAN port number Mac Address Displays the MAC address IP Address Displays the IP address if ServerView agent is installed to the OS Display Parameter Description...

Страница 61: ...Upper Warning Level Displays an upper temperature warning Upper Critical Level Displays an upper level temperature error Lower Warning Level Displays a lower temperature warning Lower Critical Level...

Страница 62: ...62 Chapter 4 Web UI...

Страница 63: ...xplains the command line interface CLI which enables the management operation of the blade server system in the Management Blade 5 1 CLI Connection Methods 64 5 2 Basic Operations of Each Screen 66 5...

Страница 64: ...2 Start the terminal software in the management terminal and perform the following port settings 3 Sets the terminal software of the management terminal to VT100 For more details about how to set term...

Страница 65: ...nt terminal and specify the IP address and port number of the Management Blade to connect the Management Blade to the management terminal Default value IP address 192 168 1 1 subnet mask 255 255 255 0...

Страница 66: ...er strings in accordance with the directions displayed on the screen after the symbol If effect after reboot is displayed on the screen it is necessary to restart the Management Blade after changing s...

Страница 67: ...during Management Blade operations the following login screen will appear If the Management Blade is not operating connect the power supply cable A self diagnostic test message appears and then the lo...

Страница 68: ...mode display the master mode login screen using one of the following methods Change the connection destination of the serial interface to the Management Blade operating in master mode Enter the userna...

Страница 69: ...normally used 3 Console Redirection Console redirection of Server Blade and Switch Blade is used 5 4 3 Console Redirection p 132 4 TFTP update Not normally used 5 Logout Performs logout 5 4 4 Logout p...

Страница 70: ...urns Management Blade settings to default Set System Default 1_9 p 117 10 Server Blade CMOS Backup Restore Performs the backup of and restores information specified by the BIOS setup utility of the Se...

Страница 71: ...become valid after restarting the Management Blade 4 Set Management Agent Default Route Not normally used Set to LAN 5 Set Management Agent DHCP Configure enable disable Sets whether to set the IP add...

Страница 72: ...he Web UI 11 Automatically Adjust Clock for Daylight Saving Changes Not supported Do not set 12 Agent HTTP Sets the HTTP agents in the Management Blade 12 Agent HTTP 1_1_12 p 73 13 Agent SNMP Sets the...

Страница 73: ...e enable disable Sets whether HTTP SSL is to be used Important In order to use SSL it is necessary to enable SSL version 3 only in the Web browser Also if SSL version 2 is enabled in the Web browser c...

Страница 74: ...Display Button in ServerView is used 3 Agent SNMP Trap Table Sets and displays a SNMP trap destination table 3 Agent SNMP Trap Table 1_1_13_3 p 75 4 Agent SNMP Community String Table Sets and displays...

Страница 75: ...ing applications such as ServerView that perform communication using SNMP community names must be set Set a community name for which communication can be performed Agent SNMP Trap Table page_1_1_13_3...

Страница 76: ...ent Blade SNMP IP Filter Table page_1_1_13_5 1 SNMP IP Filter 1 255 255 255 255 2 SNMP IP Filter 2 0 0 0 0 3 SNMP IP Filter 3 0 0 0 0 4 SNMP IP Filter 4 0 0 0 0 5 SNMP IP Filter 5 0 0 0 0 6 SNMP IP Fi...

Страница 77: ...ade 3 Telnet IP Filter Table Performs IP settings that permit Telnet service 3 Telnet IP Filter Table 1_1_14_3 p 77 4 Telnet Disconnection The Telnet connection is forcibly turned OFF Perform operatio...

Страница 78: ...ameter Setting Contents 1 Set NTP ENABLE enable disable Sets NTP enable disable If NTP is enabled the time of the Management Blade is synchronized with the NTP server periodically Specify the synchron...

Страница 79: ...Sync Afterward Sync Always Specify the time synchronization mode Sync Afterward The time of the Management Blade is synchronized to the time of the NTP server only when the time of the NTP server is f...

Страница 80: ...n 100 Full Mode 100 Half Mode 10 Full Mode 10 Half Mode Sets the NIC transmission rate Auto Negotiation auto negotiation 100 Full Mode 100Mbps full duplex secure 100 Half Mode 100Mbps half duplex secu...

Страница 81: ...Manufacture Displays the manufacturer Management Blade Manufacture Date Displays the manufacture date Management Blade Serial Number Displays the serial number Management Blade Product Name Displays...

Страница 82: ...is Table 1_3_5 p 93 6 System UPS Not used 7 System KVM Switches which Server Blade of which slot is to be used for the keyboard display mouse connected to the chassis 8 System LED Control on off blink...

Страница 83: ...o the chassis Number of Temperature Sensors Displays the number of the temperature sensors installed to the chassis Number of Power Supply Unit Displays the number of the PSUs installed to the chassis...

Страница 84: ...essary to make various settings to the installed Server Blades For details refer to 6 2 Points to Note about Remote Power OFF and the Shutdown Function p 139 Do not select this when performing operati...

Страница 85: ...with the other three This setting value is not supported 2 2 If two of four PSUs are failed the system can be operated with the other two Parameter Contents System Power Supply Unit 1 System Power Sup...

Страница 86: ...ect reset and set this value to 0 9 Power Supply Live Time Displays and sets the life time of the PSU Do not normally change the settings System Power Supply OVP Displays the Over Voltage Protection O...

Страница 87: ...art up enable disable Sets whether system fans operation tests are performed every time fan operations start System Fans Overall Status Displays the overall status of the system fans Important System...

Страница 88: ...stem Fan page_1_3_3_1 1 Rear1 Fan 1 2 Rear1 Fan 2 3 Rear2 Fan 1 4 Rear2 Fan 2 5 PowerUnit1 Fan 1 6 PowerUnit1 Fan 2 7 PowerUnit1 Fan 3 8 PowerUnit2 Fan 1 9 PowerUnit2 Fan 2 10 PowerUnit2 Fan 3 11 Powe...

Страница 89: ...e location of each fan Rear1 2 Fan 1 2 System fan unit internal fan PowerUnit1 2 3 4 Fan 1 3 PSU internal fan 1 power cooling fan 2 and 3 rear system fan unit System Fan Status Displays the status of...

Страница 90: ...Live Time Reset Sets the running time of the system fan unit to 0 After replacing the system fan unit click reset and set running time to 0 3 Fan Live Time Displays and sets the lifetime of the syste...

Страница 91: ...lays a list of temperature sensors and their status The settings and information of a specific temperature sensor can be displayed by selecting that sensor System Temperature 1_3_4_1_1 p 91 System Tem...

Страница 92: ...Function p 139 System Temperature Sensor Designation Displays the location of each temperature sensor Housing Left Center Right The left center and right of the chassis when looking from the front Am...

Страница 93: ...chassis serial number System Chassis Product Version Displays the chassis product version Parameter Contents System Chassis Intrusion Sensor_1 Displays the status of Sensor_1 system fan unit 1 and Sen...

Страница 94: ...o be continued via the LAN interface even if a communication failure caused by NIC error or LAN cable disconnection occurs Note When Management Blade is non redundantly configured it is necessary to s...

Страница 95: ...become critical but the management error LED will not blink or light up Parameter Contents 1 Turn on all server blades The power supply of all the installed Server Blades is turned on sequentially 2...

Страница 96: ...ntrol Information 1_4_1_1 p 97 2 Server Blade Information Displays the information of Server Blade 2 Server Blade Control Information 1_4_1_2 p 99 Server Blade page_1_4 1 Server Blade_1 ok 2 Server Bl...

Страница 97: ...de Temperature Displays the information about the temperature of the Server Blades 6 Server Blade Temperature 1_4_1_6 p 105 7 Server Blade NIC Information Displays the information about the onboard NI...

Страница 98: ...re is a fear that unexpected operations such as ACPI shutdown or power off may occur Remarks When ordering power on after ordering Server Blade power off check the power has been turned off correctly...

Страница 99: ...cture Displays the manufacturer Server Blade Manufacture Date Displays the manufacture date Server Blade Serial Number Displays the system serial number Server Blade Product Name Displays the official...

Страница 100: ...on Displays the BMC Baseboard Management Controller a micro controller that controls temperature and voltage sensors on the baseboard firmware version Server Blade PCI Add In Card Displays the install...

Страница 101: ...lays the CPU stepping CPU Status Displays the overall status of the CPU CPU Name Displays various types of CPU CPU Socket Designation Displays the location of CPU sockets CPU Manufacturer Displays the...

Страница 102: ...plays the total memory capacity 1 Server Blade Memory Information Table 1_4_1_4_1 p 102 2 Server Blade Memory Modules Table Displays the status of the installed memory modules 2 Server Blade Memory Mo...

Страница 103: ...that memory module number Memory Module Information Table 1_4_1_4_2_1 p 103 Parameter Contents Memory Module Status Displays the overall status of the memory module Memory Module Size Displays the ca...

Страница 104: ...being measured as the information about the voltage of the Server Blades Detailed information about a specific voltage can be displayed by selecting that voltage sensor number Server Voltage Informati...

Страница 105: ...threshold for voltage Server Voltage Current Value Displays the current voltage value Server Voltage Nominal Value Displays the nominal value for voltage Parameter Contents Temperature Sensor ID n n...

Страница 106: ...rature is judged to be critical level Server Temperature Lower Warning Level Displays lower level temperatures when a temperature is judged to be warning level Server Temperature Lower Critical Level...

Страница 107: ...1 Server Blade NIC IP Table Displays the Server Blade IP address if ServerView agent is installed to the OS 1 Server Blade NIC IP Table 1_4_1_7_1 p 107 2 Server Blade MAC Address Table Displays the MA...

Страница 108: ...the Server Blade 1 Server Blade Software Watchdog 1_4_1_8_1 p 109 2 Server Blade Boot Watchdog Performs OS boot monitoring for Server Blade 2 Server Blade Boot Watchdog 1_4_1_8_2 p 109 Server Blade M...

Страница 109: ...erView agent Parameter Contents Software Watchdog Time Displays the timeout time during OS hang Software Watchdog Action Displays actions during the Server Blade OS hang Software Watchdog Status Displ...

Страница 110: ...wn the OS using the ServerView agent operating on the Server Blade If ServerView is not installed to the Server Blade be sure to set 2 Set Boot Watchdog Enable to disable If the setting is enable ther...

Страница 111: ...election or type 0 to quit Switch Blade Information page_1_5_1 Administrative URL http n n n n Switch Blade Status Switch Blade Manufacture Switch Blade Manufacture Date MM DD YYYY HH DD SS Switch Bla...

Страница 112: ...ay Displays the gateway address set in the Switch Blade 14 Switch Blade IP Address Setting Value Sets the IP address for the Switch Blade Switch Blade is set by setting apply in 17 15 Switch Blade Sub...

Страница 113: ...ormation 1_5_1 Parameter Contents User_1 User_10 Adds users and sets passwords A list of users appears Changes in settings such as password of a specific user can be performed by selecting that User n...

Страница 114: ...r new name or user name to be changed 2 Change Password Enter the password to be changed 3 User Permission 0 255 Set the user privileges with the value of 0 255 that is the total of various set bitmap...

Страница 115: ...Management Blade event log Important If set to enable the number of event logs registered increases Pay attention to the remaining number of event logs and make sure not to exceed the maximum 4 Manag...

Страница 116: ...s 1 ALL Event Displays all logs 2 Informational Event Displays only informational event logs 3 Minor Event Displays only minor event logs 4 Major Event Displays only major events logs 5 Critical Event...

Страница 117: ...gement Blade Settings become valid after reboot 2 Set Username Password Default false true Returns user name and password to default In order to set to default after setting True reboot the Management...

Страница 118: ...are available for operation are displayed as Ready Displays the backup status of BIOS information of the Server Blades If backup data exists the MAC address date BIOS version is displayed The settings...

Страница 119: ...ys the BIOS version of the Server Blade that backed up BIOS information Server CMOS ID With Mac Address Displays the MAC address of the Server Blade that backed up BIOS information Backup Date Time Di...

Страница 120: ...ot to the Server Blade installed in the slot selected in CMOS Configure Restore Target BIOS information can be forcibly restored even if the MAC address and slot number of the Server Blade that backed...

Страница 121: ...lating to backup and restore of a specific Switch Blade can be performed by selecting that Switch Blade number Switch Backup Restore Configure 1_11_1 p 121 Switch Blade Last Action Last Done Backup Da...

Страница 122: ...d to the Switch Blade If set to enable automatic restore is only performed for Switch Blades newly installed to the chassis Restored setting information is saved as a Switch Blade boot file named back...

Страница 123: ...Server Blades The settings of the deployment Parameters of a specific Server Blade can be displayed and changed by selecting that Server Blade number Deployment Configuration 1_12_1 p 124 Deployment...

Страница 124: ...Reference Sets the master image directory Status of Blade Displays the current status of the Server Blade 22 Automatic Recovery Sets whether the automatic recovery function is enabled Status of Clonin...

Страница 125: ...ss Through_1 FC Pass Through_2 Displays the installed FC Pass Thru Blades Detailed information about a specific FC Pass Thru Blade can be displayed by selecting the number of that FC Pass Thru Blade F...

Страница 126: ...atus of the FC Pass Thru Blade FC Pass Through Voltage Maximum Displays the maximum voltage of the FC Pass Thru Blade FC Pass Through Voltage Minimum Displays the minimum voltage of the FC Pass Thru B...

Страница 127: ...meter Contents PHY MODULE_1 PHY MODULE_4 Displays the installed GbE Pass Thru Blades Detailed information about a specific GbE Pass Thru Blade can be displayed by selecting the number of that GbE Pass...

Страница 128: ...Thru Blade LAN Pass Through Hardware Version Displays the hardware version of the GbE Pass Thru Blade LAN Pass Through FW Version Displays the firmware version of the GbE Pass Thru Blade 8 LAN Pass Th...

Страница 129: ...lays the manufacture date FC SWITCH Serial Number Displays the system serial number FC SWITCH Product Name Displays the product name FC SWITCH Product Number Displays the product number FC SWITCH Tabl...

Страница 130: ...Blade FC SWITCH FC Subnet Mask Displays the subnet mask set in the FC Switch Blade FC SWITCH Name Displays the name set in the FC Switch Blade FC SWITCH Domain ID Displays the domain ID set in the FC...

Страница 131: ...er Storage Blade Product Name Displays the Storage Blade product name Storage Blade Product Version Displays the Storage Blade product version Storage Blade Model Name Displays the Storage Blade model...

Страница 132: ...le Redirect Server Blade 3_1 p 133 2 Console Redirect Switch Blade Performs Switch Blade console redirection 2 Console Redirect Switch Blade 3_2 p 134 3 Set Return Hotkey Ctrl a character Enter the re...

Страница 133: ...reens Screen using graphic mode cannot be output Console redirection is performed in the serial port A of the Server Blade connected to the Management Blade Using the console redirection function mana...

Страница 134: ...onsole redirection screen it is possible to return to the menu screen For details about the return hot key refer to 3 Set Return Hotkey Ctrl a character p 132 Switch Blade supports the console managem...

Страница 135: ...e main power supply and Server Blade power status is maintained If rebooted the master and slave of the Management Blade will switch When connected to the CLI using LAN interface because the connectio...

Страница 136: ...ding the chassis Management Blades and Switch Blades 2 SEL for Management Blade Displays log information of the Management Blade 3 Server Blade Configuration Status Displays the information of all ins...

Страница 137: ...formation Knowledgebase This chapter explains the specifications and operational notes of the Management Blade 6 1 Specifications 138 6 2 Points to Note about Remote Power OFF and the Shutdown Functio...

Страница 138: ...sis by default Specifications are as follows Parameter Functions and Specifications Product name Management blade External interface LAN 10BASE T 100BASE TX 1 Serial 1 Dimension Length Width Height 27...

Страница 139: ...r of the chassis and Server Blade from the Web UI or CLI When using this function note the following points When remotely turning OFF the main power of the chassis first check that the power of all th...

Страница 140: ...ded but because the log is caused by unplugging the power cable please ignore it MM DD YYYY HH MM SS Critical 49198 System overall status is critical MM DD YYYY HH MM SS Critical 49254 Power supply ov...

Страница 141: ...Explorer 26 IP address 17 26 Display 107 Settings 29 39 J Jumper pins 11 L LAN active LED 11 LAN interface 10 65 Set 16 LAN link LED 11 Login 26 67 135 Logout 135 M Management Blade 10 48 Management...

Страница 142: ...142 System fan unit 10 28 36 82 T Telnet 64 Set 29 40 76 U User name 16 46 W Web UI 16 26...

Страница 143: ...rty copyrights or other rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written permission of Fujitsu PRIMERGY BX60...

Отзывы: