35
PRIMERGY BX600 Management Blade Hardware Guide
Turning on the main power supply of the chassis starts the Network Blade and the system
fan operations. Power will be distributed to the Server Blade, but the Server Blade will not
be booted until a separate order to turn power ON is ordered.
• UPS
Not normally used. Do not set.
System Power Supply
Redundancy Mode
This item only appears when four power supply units are installed.
Sets the system power supply redundancy mode.
• 3+1: If one of four PSUs is failed, the system can be operated with the other
three.
This setting value is not supported.
• 2+2: If two of four PSUs are failed, the system can be operated with the other
two.
Power Supply Live Time
Counter
Indicates and sets the information about replacing the PSU and dummy PSU.
Component Name
Displays the names of PSU installed in PSU slots 1 - 4.
Installation Date
Inputs the installation date of the PSU/dummy PSU.
Life Time
Inputs the life time of PSU/dummy PSU (35,000h - operation time) when the PSU is
replaced.
It is measured in units of hours (hrs).
After replacing PSU/dummy PSU, click [Reset].
Expiry Date
Displays the expiry date of the PSU/dummy PSU.
Running time
Displays the running time of the PSU/dummy PSU.
Expiry Reporting Date
Displays the date when "Contact Check Box" is checked.
Status
Displays the status of the PSU/dummy PSU.
Contact Check Box
When the life time of the PSU/dummy PSU is over, check the check box after
contacting a service representative.
When [Reset] is clicked it is unchecked.
Apply
Applies the input information.
Reset
Resets after erasing the information of "Running Time", "Expiry Reporting Date", and
"Contact Check Box".
Server Blade Power
Switch
Sets the power supply of all the installed Server Blades.
• Turn on all Server Blades: all the installed Server Blades are turned on sequentially.
• Turn off all Server Blades: Select this item and click [Apply] and the confirmation
screen appears. If [YES] in the confirmation screen is clicked, "graceful shutdown
and off" will be ordered for the "Power Status" of all the installed Server Blades (For
details about "Power Status", refer to "• Power Status / Power Switch" (
Important:
When performing Server Blade power set in this item, after ordering
power ON/OFF, check that all power ON/OFF operations have been
completed by icons on Web UI etc., and then move on to the next
operation.