38
Chapter 4 Web UI
• Server Blade Power Switch
Sets the power supply of all the installed Server Blades.
- Turn on all Server Blades: all the installed Server Blades are turned on sequentially.
- Turn off all Server Blades: Select this item and click [Apply] and the confirmation screen
appears. If [YES] in the confirmation screen is clicked, "graceful shutdown and off" will be
ordered for the "Power Status" of all the installed Server Blades (For details about "Power
Status", refer to "• Power Status / Power Switch" (
• Reset management Blade
The Management Blade is rebooted in the Reset management Blade page.
Clicking [Reset Management Blade] reboots the Management Blade.
Even if the Management Blade is rebooted, the main power supply and Server Blade
power status is maintained.
If rebooted when the Management Blade is redundantly configured, the master and slave
are switched. During this 30 seconds LAN interface communication is not possible.
Contact Check Box
When the life time of the system fan unit is over, check the check box after
contacting a service representative. When [Reset] is clicked it is unchecked.
Not used for this product.
Apply
Applies the input information.
Reset
Resets after erasing the information of "Running Time", "Expiry Reporting
Date", and "Contact Check Box". Not used for this product.
When performing Server Blade power set in this item, check that all power ON/OFF
operations have been completed by icons on Web UI etc. and then move on to the next
operation, after ordering power ON/OFF.
Display/Parameter
Description