User Manual
Page 28 of 77
(PVI-6000-OUTD-US-W Rev.2.0)
Fig.13 AURORA with front panel
After replacing the front panel, tighten the screws to 1.5 Nm (13.2 in-lbs) to ensure
proper sealing.
3.9
Replacing the CR2032 lithium battery
WARNING
:
This component should only be replaced by qualified
personnel.
The AURORA inverter has a CR2032 lithium battery. When the battery is nearing
the end of its life, a corresponding message appears on the LCD display.
To replace the battery, remove the front panel (see Fig. 13) to get access to the
battery holder shown in Fig. 14.
Note that the battery will not fit into its holder when pressed from the top down.
Instead, slide the battery into its holder from the side, while holding it tilted at a
30° angle.
Fig. 14 Battery in place