User Manual
Page 36 of 77
(PVI-6000-OUTD-US-W Rev.2.0)
LEDs Status
Operational Status
Remarks
1 green:
yellow:
red:
Inverter is not
operating
Input voltage less than
50Vdc at the input
2 green:
yellow:
red:
Inverter is initializing,
loading settings and
performing grid check
It is a transition status
while operating conditions
are checked
3 green:
yellow:
red:
Inverter is powering
the grid
Normal operation
4 green:
yellow:
red:
Inverter is shut down
because of a GFI fault
Ground fault has been
detected
5 green:
yellow:
red:
Inverter defected a
fault
The fault can be inside or
outside the inverter. See
the alarm code appearing
on the LCD
6 green:
yellow:
red:
Installation phase:
inverter is
disconnected from grid
During installation it
refers to setup of the
address for RS-485
communication
7 green:
yellow:
red:
Inverter is
disconnected from grid
Indicates a missing grid
connection
NOTE
: Inverter status is indicated by the corresponding LEDs and by a
display message that provides a description of operation or fault
condition (see next sections).
Содержание AURORA PVI-6000-OUT-US-W
Страница 1: ...AURORA Wind Inverters INSTALLATION AND OPERATION MANUAL Model number PVI 6000 OUT US W Rev 2 0...
Страница 32: ...User Manual Page 32 of 77 PVI 6000 OUTD US W Rev 2 0 Fig 17 Data Transmission Options...
Страница 60: ...User Manual Page 60 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 73: ...User Manual Page 73 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 74: ...User Manual Page 74 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 75: ...User Manual Page 75 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 76: ...User Manual Page 76 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 77: ...User Manual Page 77 of 77 PVI 6000 OUTD US W Rev 2 0...