User Manual
Page 46 of 77
(PVI-6000-OUTD-US-W Rev.2.0)
8A)
Igrid: Measured instant grid current
Fgrid: Measured instant grid frequency
9A)
Vin: input voltage value
Iin1: Instant input current value
10A)
Pin: Measured instant input power
11A)
Riso: Measured insulation resistance. Unlike the parameters discussed above, this
is not an instant value but a measurement taken one time during inverter start-up.
12A)
If all items described above are tested OK, the inverter shows a corresponding
message in the display top line along with date and time. Clock malfunctioning or
other non function-related faults (meaning such faults that do not affect the
inverter's ability to generate energy) are shown in the bottom line of the display in
place of date and time.
Inverter OK
Wed 17 May 11
23
Riso 0.0 Mohm
Ileak 73 mA
Pin 0 W
Vin 0 V
I in 0.0 A
Igrid 0.8 A
Fgrid 50.18 Hz