User Manual
Page 18 of 77
(PVI-6000-OUTD-US-W Rev.2.0)
3.3
Selecting the place of installation
The installation place should be selected based on the following considerations:
¾
Height from ground level should be enough to ensure that display and status
LEDs are easy to read.
¾
Select a well ventilated place sheltered from direct sun radiation. Choose a
place that allows unobstructed airflow around the unit.
¾
Allow sufficient room around the unit to enable easy installation and removal
from the mounting surface.
¾
A door is provided on the unit’s front panel for hardware maintenance purpose.
The USB port for software connection is on the right side of the inverter
(protected by a cover); installation should provide free access to this side,
otherwise you will have to remove the unit from its mounting surface during
maintenance operations.
The following figure shows the recommended minimum clearances around the
inverter:
<<
Fig.5. Minimum clearances around AURORA inverter
8”
6”
6”
2”
Содержание AURORA PVI-6000-OUT-US-W
Страница 1: ...AURORA Wind Inverters INSTALLATION AND OPERATION MANUAL Model number PVI 6000 OUT US W Rev 2 0...
Страница 32: ...User Manual Page 32 of 77 PVI 6000 OUTD US W Rev 2 0 Fig 17 Data Transmission Options...
Страница 60: ...User Manual Page 60 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 73: ...User Manual Page 73 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 74: ...User Manual Page 74 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 75: ...User Manual Page 75 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 76: ...User Manual Page 76 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 77: ...User Manual Page 77 of 77 PVI 6000 OUTD US W Rev 2 0...