¾
constant monitoring of the grid voltage to ensure that voltage and frequency
remain within the specified limits (in accordance with the UL 1741 standard);
¾
automatic power limit based on internal temperature monitoring to avoid
overheating (heat sink temperature
≤
70°C [158°F]).
The redundancy of safety features implemented in the AURORA inverter
guarantees completely safe operations under any conditions
3
INSTALLATION
WARNING
: The electrical installation of AURORA must be performed
in compliance with applicable local and national standards and laws.
WARNING
: The connection of AURORA to the electrical distribution
grid must be performed only after receiving authorization from the utility
that operates the grid
3.1
Package Inspection
NOTE:
The shipper delivered your AURORA inverter to the carrier
safely packaged and in perfect condition. Upon acceptance of the package,
the carrier assumes responsibility for its safe delivery. In spite of careful
handling during transportation, damage to package or its contents
sometimes occurs.
The customer is encouraged to perform the following checks:
¾
Inspect the shipping box for apparent damage, such as holes, cracking, or any
signs of possible damage to its contents.
¾
Record any damage or shortage in the receiving documents and have the
carrier sign his/her full name.
¾
Open the shipping box and inspect the contents for internal damage. While
unpacking, be careful not to discard any equipment, parts or manuals. If any
damage is detected, call the delivering carrier to determine the appropriate
action. Save all shipping material in case the carrier should send an inspector
to verify damage!
¾
If the inspection reveals damage to the AURORA inverter, call your supplier,
or authorized distributor. They will determine if the equipment should be
returned for repair. They will also provide instructions on how to get the
equipment repaired.
¾
It is the customer's responsibility to file a claim with the carrier. Failure to file
a claim with the carrier may void all warranty service rights for any damage.
Содержание AURORA PVI-6000-OUT-US-W
Страница 1: ...AURORA Wind Inverters INSTALLATION AND OPERATION MANUAL Model number PVI 6000 OUT US W Rev 2 0...
Страница 32: ...User Manual Page 32 of 77 PVI 6000 OUTD US W Rev 2 0 Fig 17 Data Transmission Options...
Страница 60: ...User Manual Page 60 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 73: ...User Manual Page 73 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 74: ...User Manual Page 74 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 75: ...User Manual Page 75 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 76: ...User Manual Page 76 of 77 PVI 6000 OUTD US W Rev 2 0...
Страница 77: ...User Manual Page 77 of 77 PVI 6000 OUTD US W Rev 2 0...