Installation and Operator’s Manual
Page 29 of 108
(PVI-3.0/3.6/4.2-OUTD-x-US Rev: 2.1)
3.3.3
Aurora Switch Box Description
Fig. 11 - SB-01 – DC Switch Box Layout
Pos. Fig. SB-01
Description
A
DC and AC Power cable knockouts – SIZE: G1"
B
Silkscreen "ON" / "OFF"
C DC
Switch
D
Signal cable entries – SIZE: G1" ½
WARNING
: The Switch Box disconnects the DC current from the
photovoltaic panels when the switch is in “OFF” position (see the electrical
schematics in Fig.11 SD-01 – Electrical Schematics DC Switch Box" and
DOES NOT disconnect the AC line going to the Grid. To disconnect the
inverter from the AC Grid, the AC switch (not included in the Switch Box)
must be disconnected (see Fig. 9 - "Connection Diagram").