Installation and Operator’s Manual
Page 61 of 108
(PVI-3.0/3.6/4.2-OUTD-x-US Rev: 2.1)
Message Warning Error
type
Description
Z Grid HI
W008
//
Z grid out of range
Impedance outside range
Int.Error // E024
Unknown
Error
–
Internal Error
---------
//
E025
Riso Low (Log Only)
Low insulation resistance (Log only)
Int.Error // E026
Vref
Error
Wrong reference voltage (VRef)
Int.Error // E027
Vgrid
Measures
Fault
Grid voltage (VGrid) misreading
Int.Error // E028
Fgrid
Measures
Fault
Grid frequency (FGrid) misreading
Int.Error // E029
Zgrid
Measures
Fault
Grid impedance (ZGrid) misreading
Int.Error // E030
Ileak
Measures
Fault
Leak current (ILeak) misreading
Int.Error // E031
Wrong
V
Measure
Voltage (V) misreading
Int.Error // E032
Wrong
I
Measure
Current (I) misreading
Fan Fail
W010
//
Fan Fail (No disconnection)
Fan faulty (Log Only)
Int.Error // E033
UnderTemperature
Internal temperature
//
E034
Interlock Fail (Not Used)
//
E035
Remote
Off
Remote power-off
//
E036
Vout
Avg
Average output voltage outside range
W012
//
Clock Battery Low (No disconnection)
Clock battery low (not operating)
W013
//
Clock Failure (No disconnection)
Clock faulty (not operating)
Содержание AURORA PVI-3.0-OUTD-S-US
Страница 52: ...Installation and Operator s Manual Page 52 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 Fig 17 USB Port ...
Страница 80: ...Installation and Operator s Manual Page 80 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...
Страница 104: ...Installation and Operator s Manual Page 104 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...
Страница 105: ...Installation and Operator s Manual Page 105 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...
Страница 106: ...Installation and Operator s Manual Page 106 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...
Страница 107: ...Installation and Operator s Manual Page 107 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...
Страница 108: ...Installation and Operator s Manual Page 108 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...