Installation and Operator’s Manual
Page 27 of 108
(PVI-3.0/3.6/4.2-OUTD-x-US Rev: 2.1)
Fig. 9 - Electrical Connection Diagram
WARNING
: Always open the AC disconnect switch to disconnect the
Aurora inverter from the Grid before opening the DC disconnect switch.
WARNING
: To avoid the risk of electric shock from energy stored in
capacitors, wait 5 minutes after disconnecting both AC and DC sides before
opening the front panel.
WARNING
: A requirement, when selecting the electrical cables, is to
carefully evaluate the nominal operating voltage, the insulation rating, the
max operating temperature, the current rating, and the flammability rating in
accordance with the local safety standards.
When selecting the wire for the installation, the correct size needs to be
selected in order to avoid efficiency loses. Refer to Table CN-01 (section
3.3.6) "AC Grid Connections" to select the cable size.
The electrical power and signals wiring from the inverter to the AC Grid and
to the photovoltaic panel are connected through the Switch Box as described
in Fig.11 SB-01 – "DC Switch Box Layout" –using the access windows in
pos “A” for the power cables and the windows in pos “D” for the signal
cables.
Содержание AURORA PVI-3.0-OUTD-S-US
Страница 52: ...Installation and Operator s Manual Page 52 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 Fig 17 USB Port ...
Страница 80: ...Installation and Operator s Manual Page 80 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...
Страница 104: ...Installation and Operator s Manual Page 104 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...
Страница 105: ...Installation and Operator s Manual Page 105 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...
Страница 106: ...Installation and Operator s Manual Page 106 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...
Страница 107: ...Installation and Operator s Manual Page 107 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...
Страница 108: ...Installation and Operator s Manual Page 108 of 108 PVI 3 0 3 6 4 2 OUTD x US Rev 2 1 ...