Caution
The regulator parameters are overwritten. The factory settings are
stored in the regulator.
Activation of prog. no. 6205:
The regulator is reset to factory setting.
Check no. heat source 1 (6212), Check no. heat source 2
(6213), Check no. storage tank (6215) and Check no. heating
circuits (6217)
The standard device generates a check number to identify the system
scheme; this comprises the numbers listed in the table below.
Tab.23 Check no. heat source 1 (prog.-no. 6212)
Solar
A collector field
with sensor B6
and collector pump
Q5
Tank charging
pump for
buffer storage tank
K8
Solar diverting
valve for
buffer storage tank
K8
Solar charging
pump for
swimming pool K18
Solar diverting
valve for
swimming pool K18
External solar ex
changer, Solar
pump K9
DHW=DHW stor
age tank
B=Buffer storage
tank
0
No solar
1
3
DHW/B
5
X
6
X
8
X
DHW+B
9
X
DHW/B
10
X
DHW
11
X
DHW
12
X
P
13
X
P
14
X
15
X
17
X
DHW/B
18
X
DHW/B
19
X
X
20
X
X
22
X
DHW+B
23
X
X
DHW/B
24
X
X
DHW
25
X
X
DHW
26
X
X
P
27
X
X
P
(1) The domestic hot water storage tank is charged using collector pump Q5
Tab.24 Check no. storage tank (prog.-no. 6215)
Buffer storage tank
Domestic water storage tank
0
No buffer storage tank
00
No DHW storage tank
1
Buffer storage tank
01
Immersion heater
2
Buffer storage tank, solar connection
02
Solar connection
9 Settings
112
Paramount four 30 – 115 kW