30
Inspection &Service
1.
A PEEBD stored in an environmentally controlled facility, shall notbe
considered to be ingood working order since it was last serviced. It is recommended
that the PEEBD receive an Annual Inspection every 12-months by an OEM Approved
Inspection facility.
2.
If the PEEBDis used regularly for training purposes in saltwater, chlorinated,
or silted fresh water, the PEEBD will require an OEM Approved Inspectionevery
three-months, or whenever it is suspected that moisture has entered the system. The
PEEBD should receive a visual inspection prior to each use by a trained/authorised
person, and if any fault is located within the system, removed from service and receive a
complete inspection.
3.
Use in chlorinated swimming pool waterwill accelerate the deterioration of
most rubber component and require more frequent service.
4.
Unauthorized dis-assembly or inspection of the PEEBD is not allowed. All
Inspections of the PEEBD shall be conducted by an OEM Approved Inspection Facility
andor authorized personnel
Levels of Inspection
Training Systems
Visual inspection prior to use - Qualified/Certified
PersonnelDepot Level Inspection every3 months –
Qualified/Certifiedpersonnel
Annual Inspection (every 12 months)–
Qualified/Certifiedpersonnel
In Use Systems
Visual Prior to Use Inspection - Qualified/Trained
PersonnelAnnual Inspection (every12 month–
Qualified/Certifiedpersonnel
Storage in warehouse
environmentally
controlled conditions
as per OEMrequirements
Visual Inspection prior to issue from stores (not to
exceed 24-month interval) – Qualified/Certified person
Two Year Depot Inspection - Qualified/Certified
Personnel