User’s Manual
378
APS Protocol:
Object
Description
•
Enable
Automatic Protection Switching protocol information transportation based on
transmitting/receiving R-APS/L-APS PDU can be enabled/disabled. Must be
enabled to support ERPS/ELPS implementing APS. This is only valid with one
Peer MEP configured.
•
Priority
The priority to be inserted as PCP bits in TAG (if any).
•
Cast
Selection of APS PDU transmitted unicast or multi-cast. The unicast MAC will be
taken from the 'Unicast Peer MAC' configuration. Unicast is only valid for L-APS -
see 'Type'. The R-APS PDU is always transmitted with multi-cast MAC described
in G.8032.
•
Type
R-APS
: APS PDU is transmitted as R-APS - this is for ERPS.
L-APS
: APS PDU is transmitted as L-APS - this is for ELPS.
•
Last Octet
This is the last octet of the transmitted and expected RAPS multi-cast MAC. In
G.8031 (03/2010) a RAPS multi-cast MAC is defined as 01-19-A7-00-00-XX. In
current standard the value for this last octet is '01' and the usage of other values
is for further study.
Buttons
: Click to go to Fault Management page.
: Click to go to Performance Monitor page.
: Click to refresh the page immediately.
: Click to save changes.
:
Click to undo any changes made locally and revert to previously saved values.
4.20.3 Ethernet Ring Protocol Switch
The Ethernet Ring Protection Switch instances are configured here; screen in
Figure 4-20-3
appears.
Figure 4-20-3:
Ethernet Ring Protocol Switch page screenshot
Содержание IGS-10020
Страница 1: ...User s Manual...
Страница 31: ...User s Manual 31 IGS 10020PT IGS 10020PT Dimensions W x D x H 72 x 107 x 152mm...
Страница 32: ...User s Manual 32 IGS 10020HPT IGS 10020HPT Dimensions W x D x H 72 x 107 x 152mm...
Страница 33: ...User s Manual 33 IGS 10080MFT IGS 10080MFT Dimensions W x D x H 72 x 107x 152mm...
Страница 34: ...User s Manual 34 IGS 12040MT IGS 12040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 35: ...User s Manual 35 IGS 20040MT IGS 20040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 36: ...User s Manual 36 IGS 20160HPT IGS 20160HPT Dimensions W x D x H 84 x 107 x 152mm...
Страница 46: ...User s Manual 46 Figure 2 16 IGS 10080MFT Upper Panel Figure 2 17 IGS 12040MT Upper Panel...
Страница 47: ...User s Manual 47 Figure 2 18 IGS 20040MT Upper Panel Figure 2 19 IGS 20160HPT Upper Panel...
Страница 181: ...User s Manual 181 Figure 4 8 2 Multicast Flooding Figure 4 8 3 IGMP Snooping Multicast Stream Control...