Ethernet Type
: Only Ethernet Type frames can match this ACE. The IEEE
802.3 describes the value of Length/Type Field specifications to be greater
than or equal to 1536 decimal (equal to 0600 hexadecimal).
■
: Only ARP frames can match this ACE. Notice the ARP frames won't
match the ACE with Ethernet type.
■
IPv4
: Only IPv4 frames can match this ACE. Notice the IPv4 frames won't
match the ACE with Ethernet type.
■
IPv6
: Only IPv6 frames can match this ACE. Notice the IPv6 frames won't
match the ACE with Ethernet type.
•
Action
Specify the action to take with a frame that hits this ACE.
■
Permit
: The frame that hits this ACE is granted permission for the ACE
operation.
■
Deny
: The frame that hits this ACE is dropped.
•
Rate Limiter
Specify the rate limiter in number of base units.
The allowed range is 1 to 16.
Disabled indicates that the rate limiter operation is disabled.
•
EVC Policer
Select whether EVC policer is enabled or disabled. The default value is "Disabled".
Note that the ACL rate limiter and EVC policer can not both be enabled.
•
EVC Policer ID
Select which EVC policer ID to apply on this ACE. The allowed values are
Disabled
or the values
1
through
256
.
•
Port Redirect
Frames that hit the ACE are redirected to the port number specified here. The allowed
range is the same as the switch port number range.
Disabled
indicates that the port
redirect operation is disabled.
•
Mirror
Specify the mirror operation of this port. The allowed values are:
Enabled
: Frames received on the port are mirrored.
Disabled
: Frames received on the port are not mirrored.
The default value is "Disabled".
•
Logging
Specify the logging operation of the ACE. The allowed values are:
■
Enabled
: Frames matching the ACE are stored in the System Log.
■
Disabled
: Frames matching the ACE are not logged.
Note
: The logging feature only works when the packet length is less than 1518(without
VLAN tags) and the System Log memory size and logging rate is limited.
•
Shutdown
Specify the port shut down operation of the ACE. The allowed values are:
■
Enabled
: If a frame matches the ACE, the ingress port will be disabled.
■
Disabled
: Port shut down is disabled for the ACE.
Note
: The shutdown feature only works when the packet length is less than
1518(without VLAN tags).
•
Counter
The counter indicates the number of times the ACE was hit by a frame.
Содержание IGS-10020
Страница 1: ...User s Manual...
Страница 31: ...User s Manual 31 IGS 10020PT IGS 10020PT Dimensions W x D x H 72 x 107 x 152mm...
Страница 32: ...User s Manual 32 IGS 10020HPT IGS 10020HPT Dimensions W x D x H 72 x 107 x 152mm...
Страница 33: ...User s Manual 33 IGS 10080MFT IGS 10080MFT Dimensions W x D x H 72 x 107x 152mm...
Страница 34: ...User s Manual 34 IGS 12040MT IGS 12040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 35: ...User s Manual 35 IGS 20040MT IGS 20040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 36: ...User s Manual 36 IGS 20160HPT IGS 20160HPT Dimensions W x D x H 84 x 107 x 152mm...
Страница 46: ...User s Manual 46 Figure 2 16 IGS 10080MFT Upper Panel Figure 2 17 IGS 12040MT Upper Panel...
Страница 47: ...User s Manual 47 Figure 2 18 IGS 20040MT Upper Panel Figure 2 19 IGS 20160HPT Upper Panel...
Страница 181: ...User s Manual 181 Figure 4 8 2 Multicast Flooding Figure 4 8 3 IGMP Snooping Multicast Stream Control...