User’s Manual
363
4.18.6 RMON History Status
This page provides a detail of RMON history entries; screen in
Figure 4-18-6
appears.
Figure 4-18-6:
RMON History Overview page Screenshot
The page includes the following fields:
Object
Description
•
History Index
Indicates the index of History control entry.
•
Sample Index
Indicates the index of the data entry associated with the control entry.
•
Sample Start
The value of sysUpTime at the start of the interval over which this sample was
measured.
•
Drop
The total number of events in which packets were dropped by the probe due to
lack of resources.
•
Octets
The total number of octets of data (including those in bad packets) received on
the network.
•
Pkts
The total number of packets (including bad packets, broadcast packets, and
multicast packets) received.
•
Broadcast
The total number of good packets received that were directed to the broadcast
address.
•
Multicast
The total number of good packets received that were directed to a multicast
address.
CRC Errors
The total number of packets received that had a length (excluding framing bits,
but including FCS octets) of between 64 and 1518 octets, inclusive, but had
either a bad Frame Check Sequence (FCS) with an integral number of octets
(FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).
•
Undersize
The total number of packets received that were less than 64 octets.
•
Oversize
The total number of packets received that were longer than 1518 octets.
•
Frag.
The number of frames whose size is less than 64 octets received with invalid
CRC.
•
Jabb.
The number of frames whose size is larger than 64 octets received with invalid
CRC.
•
Coll.
The best estimate of the total number of collisions in this Ethernet segment.
Содержание IGS-10020
Страница 1: ...User s Manual...
Страница 31: ...User s Manual 31 IGS 10020PT IGS 10020PT Dimensions W x D x H 72 x 107 x 152mm...
Страница 32: ...User s Manual 32 IGS 10020HPT IGS 10020HPT Dimensions W x D x H 72 x 107 x 152mm...
Страница 33: ...User s Manual 33 IGS 10080MFT IGS 10080MFT Dimensions W x D x H 72 x 107x 152mm...
Страница 34: ...User s Manual 34 IGS 12040MT IGS 12040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 35: ...User s Manual 35 IGS 20040MT IGS 20040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 36: ...User s Manual 36 IGS 20160HPT IGS 20160HPT Dimensions W x D x H 84 x 107 x 152mm...
Страница 46: ...User s Manual 46 Figure 2 16 IGS 10080MFT Upper Panel Figure 2 17 IGS 12040MT Upper Panel...
Страница 47: ...User s Manual 47 Figure 2 18 IGS 20040MT Upper Panel Figure 2 19 IGS 20160HPT Upper Panel...
Страница 181: ...User s Manual 181 Figure 4 8 2 Multicast Flooding Figure 4 8 3 IGMP Snooping Multicast Stream Control...