User’s Manual
246
•
TCP RST
Specify the TCP "Reset the connection" (RST) value for this ACE.
■
0
: TCP frames where the RST field is set must not be able to match this
entry.
■
1
: TCP frames where the RST field is set must be able to match this entry.
■
Any
: Any value is allowed ("don't-care").
•
TCP PSH
Specify the TCP "Push Function" (PSH) value for this ACE.
■
0
: TCP frames where the PSH field is set must not be able to match this
entry.
■
1
: TCP frames where the PSH field is set must be able to match this entry.
■
Any
: Any value is allowed ("don't-care").
•
TCP ACK
Specify the TCP "Acknowledgment field significant" (ACK) value for this ACE.
■
0
: TCP frames where the ACK field is set must not be able to match this
entry.
■
1
: TCP frames where the ACK field is set must be able to match this entry.
■
Any
: Any value is allowed ("don't-care").
•
TCP URG
Specify the TCP "Urgent Pointer field significant" (URG) value for this ACE.
■
0
: TCP frames where the URG field is set must not be able to match this
entry.
■
1
: TCP frames where the URG field is set must be able to match this entry.
■
Any
: Any value is allowed ("don't-care").
Ethernet Type Parameters
The Ethernet Type parameters can be configured when Frame Type "Ethernet Type" is selected.
Object
Description
•
EtherType Filter
Specify the Ethernet type filter for this ACE.
■
Any
: No EtherType filter is specified (EtherType filter status is
"don't-care").
■
Specific
: If you want to filter a specific EtherType filter with this ACE,
you can enter a specific EtherType value. A field for entering a
EtherType value appears.
•
Ethernet Type Value
When "Specific" is selected for the EtherType filter, you can enter a specific
EtherType value.
The allowed range is
0x600
to
0xFFFF
but excluding 0x800(IPv4), 0x806(ARP)
and 0x86DD(IPv6). A frame that hits this ACE matches this EtherType value.
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
: Return to the previous page.
Содержание IGS-10020
Страница 1: ...User s Manual...
Страница 31: ...User s Manual 31 IGS 10020PT IGS 10020PT Dimensions W x D x H 72 x 107 x 152mm...
Страница 32: ...User s Manual 32 IGS 10020HPT IGS 10020HPT Dimensions W x D x H 72 x 107 x 152mm...
Страница 33: ...User s Manual 33 IGS 10080MFT IGS 10080MFT Dimensions W x D x H 72 x 107x 152mm...
Страница 34: ...User s Manual 34 IGS 12040MT IGS 12040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 35: ...User s Manual 35 IGS 20040MT IGS 20040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 36: ...User s Manual 36 IGS 20160HPT IGS 20160HPT Dimensions W x D x H 84 x 107 x 152mm...
Страница 46: ...User s Manual 46 Figure 2 16 IGS 10080MFT Upper Panel Figure 2 17 IGS 12040MT Upper Panel...
Страница 47: ...User s Manual 47 Figure 2 18 IGS 20040MT Upper Panel Figure 2 19 IGS 20160HPT Upper Panel...
Страница 181: ...User s Manual 181 Figure 4 8 2 Multicast Flooding Figure 4 8 3 IGMP Snooping Multicast Stream Control...