User’s Manual
358
protocol.
InNUcastPkts
: The number of broad-cast and multi-cast packets delivered
to a higher-layer protocol.
InDiscards
: The number of inbound packets that are discarded even the
packets are normal.
InErrors
: The number of inbound packets that contains errors preventing
them from being deliverable to a higher-layer protocol.
InUnknownProtos
: the number of the inbound packets that is discarded
because of the unknown or un-support protocol.
OutOctets
: The number of octets transmitted out of the interface , including
framing characters.
OutUcastPkts
: The number of uni-cast packets that request to transmit.
OutNUcastPkts
: The number of broad-cast and multi-cast packets that
requests to transmit.
OutDiscards
: The number of outbound packets that is discarded event the
packets are normal.
OutErrors
: The number of outbound packets that could not be transmitted
because of errors.
OutQLen
: The length of the output packet queue (in packets).
•
Sample Type
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute
: Get the sample directly.
Delta
: Calculate the difference between samples (default).
•
Value
The value of the statistic during the last sampling period.
•
Startup Alarm
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Rising
Trigger alarm when the first value is larger than the rising threshold.
Falling
Trigger alarm when the first value is less than the falling threshold.
RisingOrFalling
Trigger alarm when the first value is larger than the rising
threshold or less than the falling threshold (default).
•
Rising Threshold
Rising threshold value (-2147483648-2147483647).
•
Rising Index
Rising event index (1-65535).
•
Falling Threshold
Falling threshold value (-2147483648-2147483647)
•
Falling Index
Falling event index (1-65535).
Buttons
: Click to add a new community entry.
: Click to apply changes
:
Click to undo any changes made locally and revert to previously saved values.
Содержание IGS-10020
Страница 1: ...User s Manual...
Страница 31: ...User s Manual 31 IGS 10020PT IGS 10020PT Dimensions W x D x H 72 x 107 x 152mm...
Страница 32: ...User s Manual 32 IGS 10020HPT IGS 10020HPT Dimensions W x D x H 72 x 107 x 152mm...
Страница 33: ...User s Manual 33 IGS 10080MFT IGS 10080MFT Dimensions W x D x H 72 x 107x 152mm...
Страница 34: ...User s Manual 34 IGS 12040MT IGS 12040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 35: ...User s Manual 35 IGS 20040MT IGS 20040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 36: ...User s Manual 36 IGS 20160HPT IGS 20160HPT Dimensions W x D x H 84 x 107 x 152mm...
Страница 46: ...User s Manual 46 Figure 2 16 IGS 10080MFT Upper Panel Figure 2 17 IGS 12040MT Upper Panel...
Страница 47: ...User s Manual 47 Figure 2 18 IGS 20040MT Upper Panel Figure 2 19 IGS 20160HPT Upper Panel...
Страница 181: ...User s Manual 181 Figure 4 8 2 Multicast Flooding Figure 4 8 3 IGMP Snooping Multicast Stream Control...