cRDI
Fault Cause indicating that a CCM is received with Remote Defect Indication -
from this peer MEP.
•
cPeriod
Fault Cause indicating that a CCM is received with a period different what is
configured for this MEP - from this peer MEP.
•
cPriority
Fault Cause indicating that a CCM is received with a priority different what is
configured for this MEP - from this peer MEP.
Buttons
: Click to add a new peer MEP.
Functional Configuration
Continuity Check:
Object
Description
•
Enable
Continuity Check based on transmitting/receiving CCM PDU can be
enabled/disabled. The CCM PDU is always transmitted as Multi-cast Class 1.
•
Priority
The priority to be inserted as PCP bits in TAG (if any). In case of enable of
Continuity Check and Loss Measurement both implemented on SW based CCM,
'Priority' has to be the same.
•
Frame rate
Selecting the frame rate of CCM PDU. This is the inverse of transmission period
as described in Y.1731. This value has the following uses:
* The transmission rate of the CCM PDU.
* Fault Cause cLOC is declared if no CCM PDU has been received within 3.5
periods - see 'cLOC'.
* Fault Cause cPeriod is declared if a CCM PDU has been received with different
period - see 'cPeriod'.
Selecting 300f/sec or 100f/sec will configure HW based CCM (if possible).
Selecting other frame rates will configure SW based CCM. In case of enable of
Continuity Check and Loss Measurement both implemented on SW based CCM,
'Frame Rate' has to be the same.
Содержание IGS-10020
Страница 1: ...User s Manual...
Страница 31: ...User s Manual 31 IGS 10020PT IGS 10020PT Dimensions W x D x H 72 x 107 x 152mm...
Страница 32: ...User s Manual 32 IGS 10020HPT IGS 10020HPT Dimensions W x D x H 72 x 107 x 152mm...
Страница 33: ...User s Manual 33 IGS 10080MFT IGS 10080MFT Dimensions W x D x H 72 x 107x 152mm...
Страница 34: ...User s Manual 34 IGS 12040MT IGS 12040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 35: ...User s Manual 35 IGS 20040MT IGS 20040MT Dimensions W x D x H 72 x 107 x 152mm...
Страница 36: ...User s Manual 36 IGS 20160HPT IGS 20160HPT Dimensions W x D x H 84 x 107 x 152mm...
Страница 46: ...User s Manual 46 Figure 2 16 IGS 10080MFT Upper Panel Figure 2 17 IGS 12040MT Upper Panel...
Страница 47: ...User s Manual 47 Figure 2 18 IGS 20040MT Upper Panel Figure 2 19 IGS 20160HPT Upper Panel...
Страница 181: ...User s Manual 181 Figure 4 8 2 Multicast Flooding Figure 4 8 3 IGMP Snooping Multicast Stream Control...