How ACB Works
62
How ACB Works
The WallNet device server is connected to one of
the cubes and through it to all other cubes in the
wall.
1
WallNet receives a command, either from an
on-screen menu selection or from you via
the WallNet web pages, and proceeds to
color balance the wall.
2
The previous color adjustments in all cubes
are disabled.
3
On each display, a sensor moves into the
light path, partially blocking the displayed
picture.
4
The display is changed to one of the internal
test patterns, turning the screen red.
5
WallNet collects color and brightness data
from each of the cubes as the test pattern
changes from color to color.
6
The sensors are retracted, and the displays
return to the source picture.
7
WallNet calculates the adjustment
necessary to make all the cubes match.
8
WallNet sends these values to each cube
individually and these values are applied.
9
For some products (e.g. Margay II), a second
round of measurements and adjustment is
required. For others (e.g. cXXRP/RX/SP), a
single measurement series is enough.
Note:
By default, ACB process messages are
shown on each cube using MIP Banner 1. You can
disable this progress indicator using the
Advanced Settings section of the WallNet
Software page. (See "Advanced Settings" on
page 31.)
Содержание Wallnet
Страница 1: ...020 0567 05 19 Aug 2010 WallNet TM Setup Operation...
Страница 2: ......
Страница 14: ...What You Have in the WallNet Kit 8 Straight thru cable with RJ45 on both ends Mounting hardware DIN rail etc...
Страница 38: ...Saving the Configuration 32...
Страница 80: ...Network Use Summary 74...
Страница 84: ...Default WallNet IP Address 78...
Страница 88: ...82 WallNet Assistant Software program that finds WallNet hardware on a network...