27
Set Display IDs in the Displays
Set Display IDs in the Displays
WallNet does not go out and seek the display IDs.
You must list them for WallNet. But first you must
set them with the remote control in each display.
Set the IDs so that each display has a unique
combination of Group ID and Unit ID in that wall.
The displays respond when they are addressed
individually. You don’t want two displays
responding at the same time.
The display model User Guide has more detail
about setting the IDs and connecting the displays
for RS232 control. In general, the following steps
will work for most products, except Clarity Matrix.
1
Using the remote control, press
MENU
to
open the menu system on your display.
2
Select
ADVANCED
OPTIONS
and press
ENTER
.
3
Select
SERIAL
PORT
SETTINGS
and press
ENTER
.
4
Select
GROUP
ID
and then
UNIT
ID
. Use the
+ / – keys to scroll through the
alphanumeric characters.
5
Select the baud rate you want to use. This is
the baud rate between the WallNet box and
the displays. All displays must be set to the
same baud rate.
6
Press
PREV
to save your changes.
7
Press
MENU
to close the menu system on
your display.
✎
The baud rate is not automatically adjusted, as
when modems talk to each other and find the high-
est rate they can both use. The baud rate must be
set manually at all the displays and set manually in
WallNet.
Содержание Wallnet
Страница 1: ...020 0567 05 19 Aug 2010 WallNet TM Setup Operation...
Страница 2: ......
Страница 14: ...What You Have in the WallNet Kit 8 Straight thru cable with RJ45 on both ends Mounting hardware DIN rail etc...
Страница 38: ...Saving the Configuration 32...
Страница 80: ...Network Use Summary 74...
Страница 84: ...Default WallNet IP Address 78...
Страница 88: ...82 WallNet Assistant Software program that finds WallNet hardware on a network...