Charged Section
The places where the commercial AC power is used without
passing through the power supply transformer.
If the places are touched, there is a risk of electric shock. In addition,
the measuring equipment can be damaged if it is connected to the
GND of the charged section and the GND of the non-charged
section while connecting the set directly to the commercial AC
power supply. Therefore, be sure to connect the set via an insulated
transformer and supply the current.
1. AC Power Cord
2. AC Inlet with Filter
3. Power Switch (S1)
4. Fuse (In the SW POWER SUPPLY Module)
5. STB Transformer and Converter Transformer
(In the SW POWER SUPPLY Module)
6. Other primary side of the SW POWER SUPPLY Module
CHARGED SECTION AND HIGH VOLTAGE GENERATING POINT
7
High Voltage Generating Point
The places where voltage is 100V or more except for the charged
places described above. If the places are touched, there is a risk of
electric shock.
1. SW POWER SUPPLY Module ...................................... (215V)
2. X DRIVE Assy .............................................. (–280V to 215V)
3. Y DRIVE Assy ............................................................... (345V)
4. SCAN (A) Assy .............................................................. (345V)
5. SCAN (B) Assy ............................................................... (345V)
6. X CONNECTOR (A) Assy ........................... (–280V to 215V)
7. X CONNECTOR (B) Assy ............................ (–280V to 215V)
X DRIVE
Assy
X CONNECTOR (B)
Assy
AC Inlet with Filter
Power Cord
Power Switch
(S1)
Y DRIVE
Assy
SCAN (A)
Assy
SCAN (B)
Assy
X CONNECTOR (A)
Assy
SW POWER SUPPLY
Module
Top
Front
Fig.1 Charged Section and High Voltage Generating Point (Rear View)
: Part is the High Voltage Generating Points
other than the Charged Section.
: Part is Charged Section.
Содержание PDP 433CMX
Страница 14: ...14 PDP 433CMX Upper side 8 9 1 Upper side Upper side 9 7 5 6 2 10 10 8 8 2 5 UNDER LAYER SECTION 4 ...
Страница 26: ...26 PDP 433CMX 2 13 UPPER LAYER SECTION 2 10 10 12 SW101 100V 200V P4 P7 P3 P5 P6 P2 P1 VM1 6 7 4 8 5 1 9 3 ...
Страница 165: ...165 PDP 433CMX Pin Assignment Top View CXA3516R RGB ASSY IC4603 AD PLL IC ...
Страница 166: ...166 PDP 433CMX Block Diagram ...
Страница 167: ...167 PDP 433CMX Pin Function ...
Страница 168: ...168 PDP 433CMX ...
Страница 169: ...169 PDP 433CMX ...