9.1.1.22.2 Command: tbpos
Command
tbpos,idx,slew-rate,pos,duration
Description
Set the parameters of a row of the table-driven generator by storing them into the device's
EEPROM. A running or stopped table-driven generator is not affected.
Responses
ok
on success
nok
on failure
Query
tbpos,idx
Description
Get the parameters of a row of the table-driven generator by retrieving them from the device's
EEPROM.
Responses
tbpos,idx,slew-rate,pos,duration
on success
nok
on failure
Parameters
Description
Type: Range
Default value
idx
Index of row
W: 0 ... 99
none
slew-rate
Slew rate [V/µs]
FPV: 0.000000003 ... 0.005
0.005
pos
Position or voltage [%]
FPV: 0 ... 100
0
duration
Duration [s]
FPV: 0.1 ... 100
0.1
Errors
error-bit 28, error-bit 29, error-bit 30, error-bit 31
Examples
request: "tbpos,0,0.0003,50,50"
response: "ok"
back to command list
9.1.1.22.3 Command: tblo
Command
tblo,limit
Description
Set the lower limit of the row index of the table-driven generator. If the new lower limit is
greater than the index of the current row then the index of the current row is set to the new
lower limit. The limit is stored into the device's EEPROM. A running or stopped table-driven
generator is affected.
Responses
ok
on success
nok
on failure
Query
tblo
Description
Get the lower limit of the row index of the table-driven generator by retrieving it from the
device's EEPROM.
Responses
tblo,limit
on success
nok
on failure
Parameters
Description
Type: Range
Default value
limit
Lower limit of the row index
W: 0 ... 99
0
Errors
error-bit 28, error-bit 29, error-bit 31
Examples
request: "tblo,20"
response: "ok"