48
ID
Class
Designation
(Possible) cause/effect
Rectification/action
Quit
failed
plausibility range.
56 Info
Sensor type not defined The sensor type is not specified.
The sensor is not functional.
-
-
57 Info
Sensor input not
populated
Sensor input is not populated on IO board
circuit. Sensor is not usable.
Modify IO assignment.
-
60 Info
Actuator failure
The actuator reports an (internal) error.
-
-
61 Info
Actuator overload
The actuator reports an overload.
-
-
62 Info
Actuator overheat
The temperature monitoring of the actuator
has been triggered.
-
-
65 Info
Actuator power
monitoring defective
The power monitoring system of the actuator
has an error.
-
-
66 Info
Actuator excess power The power monitoring system of the actuator
has detected that the power limit has been
exceeded.
-
-
67 Info
Actuator insufficient
power
The power monitoring system of the actuator
has detected that the power limit has been
undercut.
-
-
68 Info
Actuator group error
Error monitoring has detected an error.
-
-
70 Info
Self-test failed
The self-test of the unit has failed.
-
-
71 Info
Plausibility check failed The unit reports an error due to a plausibility
check.
-
-
72 Info
Timeout exceeded
The unit reports an error due to exceeded
time limit.
-
-
73 Info
Pause time active
The unit cannot be activated because a pause
time must be observed.
-
-
74 Info
Maximum On-time
exceeded
The unit has deactivated itself because a time
monitoring system, which monitors the