Page 7.3
6-CHANNEL BATTERY SIMULATOR MODULE 41-752
pickering
SECTION 7 - MAINTENANCE INFORMATION
CHANNEL 1
41-752
BATTERY
SIMULATOR
MODULE
37-W
ay Male D-T
ype
37-W
ay Female D-T
ype
Vout+
Vout-
1Ω
1Ω
36Ω
Load
CHANNEL 1
41-752
BATTERY
SIMULATOR
MODULE
37-W
ay Male D-T
ype
37-W
ay Female D-T
ype
Vout+
Vout-
1Ω
1Ω
36Ω
Load
Sense+
Sense-
Figure 7.1 - Load Connection For Testing 41-752 Battery Simulator
Figure 7.2 - Sense Connections For Testing 41-752 Battery Simulator
Sense Line Operation
Connect the load as shown in Figure 7.1 to the channel under test.
Set the output voltage to +5V, and check that the voltage at the output terminals of the 41-752 is 5 Volts.
Check the voltage across the 36Ω load resistor, it should be approximately 4.74 Volts.
Connect the sense wires to the load resistor as shown in Figure 7.2.
Check the voltage across the 36Ω load resistor, it should now be 5 Volts.