YES go to 12 NO go to 13
12
- Check the earth insulation of the 4 Stepper lines.
Electric characteristic
14-23 =
>1 M
Ω
(infinite)
6-23 =
>1 M
Ω
(infinite)
21-23 =
>1 M
Ω
(infinite)
24-23 =
>1 M
Ω
(infinite)
YES go to 14 NO go to 13
13
- Repair or replace the wiring.
YES go to 11
14
- Connect the Stepper connector.
Repeat the continuity check with the tool pins.
Electric characteristic
14-24 =
approx. 51
Ω
6-21 =
approx. 51
Ω