7 Maintenance
54
Version: 2.1.1
MS222E
H-845 Hexapod System
Replacing the fuses of the M850B0448 power supply
1. Switch off the M850B0448 power supply.
2. Disconnect the M850B0448 power supply from the power socket by pulling
the power plug.
3. Wait a minute to be sure that any residual voltage has dissipated.
4. Pry open the door that covers the fuse carrier and pry out the fuse carrier (see
Figure 25 above).
5. Be sure to replace both fuses with fuses of the suitable type:
100 to 240 V ~: 2 x IEC T 8 AL (with 250 V rated voltage)
L = Low breaking
T = Time lag
Note that IEC fuses are cited: other fuse standards may require higher
nominal current rating.
6. Reinstall the carrier and close the door
7.4 Cleaning the Hexapod
Requirements
You have disconnected the hexapod from the power supply.
Cleaning the hexapod
If necessary, clean the surfaces of the hexapod with a cloth that is lightly
dampened with a mild cleanser or disinfectant.