User Manual IXE
α−
A
MA 1206-A001 GB
22
2.9 Printer
Operation
The program names, program lists, parameters or registers can be printed via the RS 232
interface.
Important:
The printer must be operated with a software-handshake, X-ON / X-OFF protocol (refer to
the printer manual)
The printer mode can be accessed when the IXEa-A-T is in the
Monitor mode
.
Instructions: DSP[name] CR Print program [name]
DSP CR Print parameters
DSR CR Print registers
DSI CR Print program list
2.9.1 Print Text in a Program
Refer to Programming manual MINILOG chapter 2.4
2.10 Error Messages
2.10.1 Programming Errors
If an instruction has not been entered correctly, Programming error (Programmierfehler)
will be displayed when an attempt is made to start the execution of the instruction with
.
If the error is detected during program run, you must go back to the Monitor mode
+
, then access the Program edition (EP[name],
) and correct the program [name].
Remark:
We recommend testing each edited program, instruction by instruction, before starting the
program execution (UP[name],
).
Refer to the remarks in chapter 2.5.
2.10.2 Error Message From the Power Stage
Display: Error : Power stage (Fehler: Endstufe)
All axes are stopped. If the unit was executing a program, the program is abandoned. The
unit must be powered off, the default eliminated and the power stage cooled-off before the
unit is powered on again.
The power stage errors are described in the corresponding manuals.