2.4 Programming
Program instructions and commands are described in the Programming manual MINILOG.
Some of these instructions only apply to the
Computer mode
or to the MINILOG
programming language. The instructions are signed by – only computer mode.
2.4.1 Program Length
The program length is variable, maximum length is 630 lines. The available memory can
be used for any number of programs, providing that the total number of program lines does
not exceed the maximum value. If several programs are stored, a memory location is used
for each program name which reduces the total number of program lines available.
2.4.2 Program List
The list of programs stored can be displayed in the
Monitor mode
with the instruction:
IP
.
The name of program No. 1 and its length in lines is displayed on the first line.
Go to the next program name:
Return to the
Monitor mode:
+
2.4.3 Program edition
Each program is stored in the CMOS-RAM memory with its name (6 characters max.).
The line number is automatically increased by one after storing the current line in memory
with (
).
Instruction: EP[name] Program edition starting with line No. 1
EP[name] Nnn Program edition starting with line nn
EP =
Program edition
[name] = Program name, 6 characters max.
N = Program line
nn
= Line number
A blank character must be introduced between the program name und N!
Example: EP2 N031 Edition of program No.2, starting at line 31