2.6.1 Error Messages During Program Run
Each error message interrupts the current program (refer to chapter 2.10 ).
If the unit displays EMERGENCY STOP, this message must be confirmed by
. The unit
switches to the
Monitor mode
. Then, it is possible to initialize the axes in the
Manual
Mode (H)
.
If the unit displays POWER STAGE ERROR, the unit must be powered off. If the error is
due to overheating, wait until the unit has cooled off. The default must be debugged in all
cases before powering the unit again.
2.7 Copy
Program
The IXEa-A-T must be in the
Monitor mode
Instruction: CP[name] [namenew]
CP = Copy program
[name] = Name of the program to be copied
[namenew] = Name given to the new program
Do not forget the blank character between the two program names!
Example: CPTEST NASA1
The program TEST is copied and renamed NASA1.
2.8 Rename
Program
The IXEa-A-T must be in the
Monitor mode
Instruction: RP[name] [namenew]
RP = Rename program
[name] = Name of the program to be renamed
[namenew] = New program name
Do not forget the blank character between the two program names!
Example: RPTEST QBF5S
The program TEST is renamed QBF5S.