phytron
®
MA 1206-A001 GB
15
2.3.2 Frequency Switching f/f'
The
key is used to modify the run frequency in the
Manual mode
:
f (f
min
): press the
key
f' (f
min
): press the
+
keys
The actual run frequency is displayed by
= f or
= f' .
2.3.3 Input of Instructions in the Manual Mode
It is possible to enter one or more instructions in the second line of the display unit when
the unit is in the
Manual mode
.
This function is activated after typing instruction I. The cursor jumps to the second line of
the display unit.
Display: MANU
X 12.34 mm
The input can include all programming instructions:
Parameter programming, initialization M0P displacement, run instructions, status requests,
output switching, register processing, etc.
After typing the various instructions, they are executed after pressing
. To enter more
commands, start again with an I instruction to place the cursor on the second display line.
Example: MANU
X 12.34 mm
X0 H XP21S0 A011 E011 X+20.5 H A010
This command line makes the unit execute the following instructions:
1. Initialize X-Axis
2. Stop and check if no emergency stop has occurred
3. Set the absolute counter to zero
4. Activate output 1
5. Wait until input 1 is activated
6. Displacement of the X-axis: 20.5 mm in the +direction
7. Stop and check if no emergency stop has occurred
8. Deactivate output 1
The sequence is started by pressing
. Once all instructions are processed, the unit
switches automatically back to the
Manual mode
and the text in the second display line
disappears.
After typing I, a new instruction can be entered or the unit moved in the
Manual mode
, or
switched back to the monitor mode by pressing
+
.