4.2.2 Delete Program
This function deletes one of the programs or all programs stored in the terminal.
Important:
The terminal must be in the PT35 mode!
Instruction: DP*
The unit displays a warning message. Confirm with J (Yes). The program name will be
deleted.
Instruction: DP[name]
The unit displays a warning message. Confirm with J (Yes). The program name will be
deleted. If the program name is not found in memory, an error message is displayed and
must be acknowledged by
.
4.2.3 Program Edition
This function allows editing programs which are stored in the terminal’s memory.
Important:
The terminal should be in the PT35-mode!
Instruction: EP[name]
You can now edit a program named NAME. If the program name has not been found, a
new program called NAME is created.