phytron
®
MA 1206-A001 GB
17
Display: MANU
X 1234.5678 mm
Y 1234.5678 mm
e1 Input 1 to 12 1001 0101 0000
In our example inputs 1,4,6,8 = ON and inputs 2,3,5,7,9,10,11,12 = OFF (deactivated)
To display the next higher input group: press
If no higher group is installed, the display goes back to the first group of inputs (e1).
To display the next lower input group: press
After input group No 1, the input group of the highest number will be displayed.
Pressing
+
erases the second line displayed, the input display mode is exited.
Output Setting
Instruction: I an,
a= keys
+ A
a = group of outputs
n= group number (a1= outputs 1-8)
The output status is displayed:
0= OFF 1 = ON
Display: MANU
X 1234.5678 mm
Y 1234.5678 mm
a1 outputs 1 to 8 1000 0001
The outputs can be modified one by one:
To modify the output status, effect the following operations:
1. Position the cursor below the output to modify
2. Overwrite the value with the desired output status
3. Confirm with
.
The cursor remains below the modified output.
Exit the output program: Press keys
+
.
The display of the second line is erased. The unit returns to the
Manual mode
.