phyCORE-LPC2292/94
122
©
PHYTEC Meßtechnik GmbH 2006 L-658e_5
Starting with PCB revision 1179.6 the phyCORE Carrier Board
HD200 features 4 solder jumper (J1-J4) that allow signal routing for
GPIO37-GPIO40 to different connectors; the Ethernet interface X7 or
the Expansion Bus X2. The standard configuration of the
phyCORE-LPC2292/94 provides Ethernet signals on these pins. As a
result the default configuration of Jumpers J1-J4 will route the signals
to Ethernet interface connector X7. Changing this jumper default
configuration allows use of the signals on the Expansion Bus in
combination with a phyCORE module lacking the Ethernet controller.
Jumper Setting
Description
J1 - J4
1 + 2*
Signals GPIO37-GPIO40 configured as Ethernet signals
routed to X7
J1 - J4
2 + 3
Signals GPIO37-GPIO40 routed to Expansion Bus
* = Default setting
Table 79:
Solder Jumpers J1 - J4 Configuration Ethernet Interface
X2
X6
X7
S2
S1
S_1
S_2
U9
P2
P1
R3
2
X1
BAT1
PHYTEC Messtechnik GmbH
PCB 1179.6
J1
J2
J3
J4
Figure 35: Location of Solder Jumpers J1 – J4 and Ethernet Interface
Connector X7
Содержание phyCORE-LPC2292/94
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE LPC2292 94 Hardware Manual Edition July 2006...
Страница 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...