Jumpers
©
PHYTEC Messtechnik GmbH 2006 L-658e_5
41
3.19
J615 CAN Bus Level Configuration
Jumper J615 is used for configuration of the CAN level power supply
on the CAN transceivers U605 and U606. In order to ensure proper
CAN_High and CAN_Low voltage levels the applicable CAN
transceiver must be supplied with the required voltage level at pin #3.
The following configurations are possible:
CAN Transceiver Supply Configuration
J615
Pin 3 on CAN transceivers U605 and U606 connected
to 5 V supply voltage VDD_V5V0
(use only with TLE6250V33 devices)
1 + 2*
Pin 3 on CAN transceivers U605 and U606 not
connected to 3.3 V supply voltage VDD_V3V3
(use only with other CAN transceivers)
2 + 3
* = Default setting
Table 28:
J615 CAN Level Configuration