phyCORE-LPC2292/94
94
©
PHYTEC Meßtechnik GmbH 2006 L-658e_5
Caution:
When using the DB-9 socket P1B with the configuration of the
phyCORE-LPC2292/94 as described above the following jumper
settings are not functional and could damage the module:
Jumper
Setting
Description
JP1
open
Pin 2 of DB-9 socket P1B not connected, no
connection to TxD1 signal from
phyCORE-LPC2292/94
JP2
closed
Pin 9 of DB-9 socket P1B connected with port P1.18
from phyCORE-LPC2292/94
JP3
closed
Pin 7 of DB-9 socket P1B connected with port P0.22
from phyCORE-LPC2292/94
JP4
closed
Pin 4 of DB-9 socket P1B connected with port /PCS0
from phyCORE-LPC2292/94
JP5
closed
Pin 6 of DB-9 socket P1B connected with MOSI0
signal from phyCORE-LPC2292/94
JP6
closed
Pin 8 of DB-9 socket P1B connected with port P0.21
from phyCORE-LPC2292/94
JP7
closed
Pin 1 of DB-9 socket P1B connected with port P1.19
from phyCORE-LPC2292/94
JP8
open
Pin 3 of DB-9 socket P1B not connected, no
connection to RxD1_ext. signal from
phyCORE-LPC2292/94
Table 55:
Improper Jumper Settings for DB-9 Socket P1B (Second RS-232)
If an RS-232 cable is connected to P1B by mistake, the voltage level
on the RS-232 lines could destroy the phyCORE-LPC2292/94.
Содержание phyCORE-LPC2292/94
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE LPC2292 94 Hardware Manual Edition July 2006...
Страница 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...