phyCORE-LPC2292/94
84
©
PHYTEC Meßtechnik GmbH 2006 L-658e_5
16.3
Functional Components on the phyCORE
Carrier Board HD200
This section describes the functional components of the phyCORE
Carrier Board HD200 supported by the
phyCORE-LPC2292/94 and appropriate jumper settings to activate
these components. Depending on the specific configuration of the
phyCORE-LPC2292/94 module, alternative jumper settings can be
used. These jumper settings are different from the factory default
settings as shown in
and enable alternative or additional
functions on the phyCORE Carrier Board HD200 depending on user
needs.
16.3.1
Power Supply at X1
Caution:
Do not use a laboratory adapter to supply power to the Carrier Board!
Power spikes during power-on could destroy the phyCORE module
mounted on the Carrier Board! Do not change modules or jumper
settings while the Carrier Board is supplied with power!
Permissible input voltage: +/-5 VDC regulated.
The required current load capacity of the power supply depends on the
specific configuration of the phyCORE-LPC2292/94 mounted on the
Carrier Board as well as whether an optional expansion board is
connected to the Carrier Board. An adapter with a minimum supply of
500 mA is recommended.
Jumper Setting
Description
JP9
1 + 2
3.3 V primary main supply voltage
to the phyCORE-LPC2292/94
JP16
2 + 3
5 V as secondary main supply voltage
to the phyCORE-LPC2292/94
Table 46:
JP9, JP16 Configuration of the Main Supply Voltages VCC / VCC2
Содержание phyCORE-LPC2292/94
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE LPC2292 94 Hardware Manual Edition July 2006...
Страница 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...