phyCORE-LPC2292/94
102
©
PHYTEC Meßtechnik GmbH 2006 L-658e_5
2.
No CAN transceiver is populating the phyCORE-LPC2292/94 and
Jumpers J603 and J605 are closed; CAN signals generated by the
CAN transceiver (U3) on the Carrier Board extending to connector
P2B
without galvanic seperation:
Jumper Setting
Description
JP33
2 + 3
Pin 2 of the DB-9 plug P2B is connected to CAN_L2 of
CAN transceiver U3 of the Carrier Board HD200
JP34
1 + 2
Pin 7 of the DB-9 plug P2B is connected to CAN_H2 of
CAN transceiver U3 of the Carrier Board HD200
JP14
2 + 4
Input at opto-coupler U6 on the Carrier Board
connected to CAN_H2/TD2 of the
phyCORE-LPC2292/94
JP15
2 + 4
1
Output at opto-coupler U7 on the Carrier Board
connected to CAN_L2/RD2 of the
phyCORE-LPC2292/94
JP13
closed
CAN transceiver and opto-coupler on the Carrier Board
connected with 5 V supply voltage
JP18
closed
GND potential at CAN transceiver and opto-coupler on
the phyCORE Carrier Board HD200
JP29
open
No power supply via CAN bus
JP39
open
No power supply via CAN bus
Table 63:
Jumper Configuration for CAN Plug P2B using the CAN Transceiver
on the Carrier Board HD200
Pin 3:
GND (Carrier Board Ground)
Pin 7:
CAN_H2 (not galvanically separated)
Pin 2:
CAN_L2 (not galvanically separated)
Pin 6:
GND (Carrier Board Ground
Figure 28: Pin Assignment of the DB-9 Plug P2B (CAN Transceiver on Carrier
Board)
1
:
Please make sure the CAN transceiver on the phyCORE-LPC2292/94 is not populated and
Jumpers J603 and J605 are closed (
refer to section 3.14 for details
).
1
2
3
4
7
6
5
8
9
Содержание phyCORE-LPC2292/94
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE LPC2292 94 Hardware Manual Edition July 2006...
Страница 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...