phyCORE-LPC2292/94
90
©
PHYTEC Meßtechnik GmbH 2006 L-658e_5
Caution:
When using the DB-9 socket P1A as RS-232 interface on the
phyCORE-LPC2292/94 the following jumper settings are not
functional and could damage the module:
Jumper
Setting
Description
JP20
open
Pin 2 of DB-9 socket P1A not connected, no
connection to TxD0 signal from
phyCORE-LPC2292/94
JP21
closed
Pin 9 of DB-9 socket P1A connected with port P1.20
from phyCORE-LPC2292/94
JP22
1 + 2
Pin 7 of DB-9 socket P1A connected with port P1.17
from phyCORE-LPC2292/94
JP23
1 + 2
Pin 4 of DB-9 socket P1A connected with MISO0
signal from phyCORE-LPC2292/94
1 + 2
Pin 6 of DB-9 socket P1A connected with SCLK0
signal from phyCORE-LPC2292/94
JP24
2 + 3
Pin 6 of DB-9 socket P1A connected with VOUT from
Carrier Board HD200
JP25
Closed
Pin 8 of DB-9 socket P1A connected with port P1.16
from phyCORE-LPC2292/94
JP26
closed
Pin 1 of DB-9 socket P1A connected with port P1.21
from phyCORE-LPC2292/94
JP27
open
Pin 3 of DB-9 socket P1A not connected, no
connection to RxD0 signal from
phyCORE-LPC2292/94
Table 52:
Improper Jumper Settings for DB-9 Socket P1A as First RS-232
If an RS-232 cable is connected to P1A, the voltage level on the
RS-232 lines could destroy the phyCORE-LPC2292/94.
Содержание phyCORE-LPC2292/94
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE LPC2292 94 Hardware Manual Edition July 2006...
Страница 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...