6 Hardware Interface
6.5.4
Differential RS-422 Inputs (G2 models)
ISO_INC0 and ISO_INC1 are isolated differential RS-422 inputs (see also Fig. 6.3). They are
connected to a Maxim MAX3098 RS-422 receiver device. Please consult the data sheet of the
MAX3098 for connection details.
Don’t connect single-ended signals to the differential inputs ISO_INC0 and
ISO_INC1 (see also Fig. 6.11).
R
X R S 4 2 2
I S O _ I N C x _ P
I S O _ I N C x _ N
1 2 p o l . H i r o s e
C o n n e c t o r
Y O U R _ G N D
5 V T T L L o g i c L e v e l
C a m
e r a
Figure 6.11: Incorrect connection to ISO_INC inputs
6.5.5
Master / Slave Camera Connection
The trigger input of one Photonfocus G2 camera can easily connected to the strobe output of
another Photonfocus G2 camera as shown in Fig. 6.12. This results in a master/slave mode
where the slave camera operates synchronously to the master camera.
I
S O _ G N D
I S O _ P W
R
P o w e r
M O S F E T
I S O _ O U T 0
P T C
4 k 7
I S O _ G N D
I S O _ G N D
I S O _ V C C
e n h a n c e d
P o w e r F E T
4 . 7 V
1 0 k
I S O _ I N 0
M a s t e r C a m
e r a
S l a v e C a m
e r a
3
7
H i r o s e
C o n n e c t o r s
+
+
I S O _ G N D
I S O _ G N D
1 2
1 2
6
I S O _ P W
R
Figure 6.12: Master / slave connection of two Photonfocus G2 cameras
.
66
Содержание MV1-R1280-50-G2 Camera Series
Страница 6: ...CONTENTS 6...
Страница 10: ...2 Introduction 10...
Страница 14: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 14...
Страница 26: ...4 Product Specification Figure 4 1 Photonfocus MV1 R1280 GigE camera series with C mount lens 26...
Страница 30: ...4 Product Specification 30...
Страница 51: ...Figure 5 19 Crosshairs Example with different grey values 5 6 Crosshairs 51...
Страница 72: ...6 Hardware Interface 72...
Страница 84: ...7 Software 84...
Страница 88: ...9 Warranty 88...
Страница 90: ...10 References 90...
Страница 94: ...B Camera Revisions 94...
Страница 95: ...C Document Revision History Revision Date Changes 1 0 April 2015 First version 95...