5.2.8
Trigger Timing Values
Table 5.3 shows the values of the trigger timing parameters.
MV1-R1280-50 GigE
MV1-R1280-50 GigE
Timing Parameter
Minimum
Maximum
t
d
−
iso
−
input
1
µ
s
1.5
µ
s
t
d
−
RS422
−
input
65 ns
185 ns
t
jitter
0
20 ns
t
trigger
−
delay
0
0.33 s
t
burst
−
trigger
−
delay
0
0.33 s
t
burst
−
period
−
time
depends on camera settings
0.33 s
t
trigger
−
offset
(non burst mode)
200 ns
duration of 1 row
t
trigger
−
offset
(burst mode)
250 ns
250 ns
t
exposure
58
µ
s
0.33 s
t
strobe
−
delay
600 ns
0.33 s
t
strobe
−
offset
(non burst mode)
200 ns
200 ns
t
strobe
−
offset
(burst mode)
250 ns
250 ns
t
strobe
−
duration
200 ns
0.33 s
t
d
−
iso
−
output
150 ns
350 ns
t
trigger
−
pulsewidth
200 ns
n/a
Number of bursts n
1
30000
Table 5.3: Summary of timing parameters relevant in the external trigger mode using camera MV1-R1280-
50 GigE
.
5.2 Trigger and Strobe
41
Содержание MV1-R1280-50-G2 Camera Series
Страница 6: ...CONTENTS 6...
Страница 10: ...2 Introduction 10...
Страница 14: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 14...
Страница 26: ...4 Product Specification Figure 4 1 Photonfocus MV1 R1280 GigE camera series with C mount lens 26...
Страница 30: ...4 Product Specification 30...
Страница 51: ...Figure 5 19 Crosshairs Example with different grey values 5 6 Crosshairs 51...
Страница 72: ...6 Hardware Interface 72...
Страница 84: ...7 Software 84...
Страница 88: ...9 Warranty 88...
Страница 90: ...10 References 90...
Страница 94: ...B Camera Revisions 94...
Страница 95: ...C Document Revision History Revision Date Changes 1 0 April 2015 First version 95...