Adjustment
85
13
.26
Adjusting the retaining finger of the end knotting equipment
Requirement
When parameter "610" is set at "1" and the machine is in the needle rise position
1. The bottom edge of retaining finger
2
should be
0.5 mm
above the hook point.
2. There should be a distance of
0.5 mm
between retaining finger
2
and the needle.
3. There should be a distance of
6 mm
between retaining finger
2
and the centre of the
needle.
●
Switch on the machine and connect it to the pneumatic system.
●
Set parameter "610" at value "1" and set needle rise position.
●
Loosen screw
1
.
●
Adjust retaining finger
2
(screw
3
) in accordance with
requirement 1
.
●
Adjust shaft
4
(screw
5
) in accordance with
requirement 2
.
●
Switch off the machine.
●
Adjust retaining finger
2
(screw
1
) in accordance with
requirement 3.
When tightening screw
1
take care to see that lever
6
engages reliably in part
7
and does not block the cylinder.
6 mm
2
64-101
2
0,5 mm
Fig. 13 - 24
64-100
2
0,5 mm
64-084
1
64-102
3
7
6
5
4