![Pfaff 3307-1 SERIES Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/pfaff/3307-1-series/3307-1-series_instruction-manual_1534291065.webp)
Adjustment
65
13
.08
Basic setting of the button clamp
Requirement
1. When the button clamp is raised, switch
1
should be operated reliably and the
distance of the clamp jaws
3
to the needle plate should be
12 mm
.
2. When the button clamp is lowered, the clamp jaws
3
should be resting parallel on the
needle plate.
Fig. 13 - 05
12 mm
3
1
4
5
2
4
4
3
3
●
Adjust switch
1
(screws
2
) and clamp jaws
3
(screws
4
) in accordance with
requirement
1
.
●
Connect the machine to the pneumatic system.
●
Switch on the machine and lower the button clamp.
●
Align clamp jaws
3
(screws
4
) in accordance with
requirement 2
.
●
Switch off the machine and disconnect it from the pneumatic system.
Ring
5
is used to limit the clamp stroke and must not be removed!