112
Adjustment
Group
Parame-
ter
Description
Setting
range
Set
value
400
411
Delay after stop cylinder on/off [s]
0,00 - 1,50
0,10
412
Delay after clamp open [s]
0,00 - 1,50
0,10
500
501
Soft start stitches
Soft start speed [min-
1]
0 - 15
0 - 2000
0
500
503
Extras stitches at start (start stitches)
0 - 4
0
504
Delay time “thread clamp at seam start”
[s]
0 - 2
0,02
506
Angle position for “end knotting on”
0 - 127
40
507
Angle position for “end knotting off”
0 - 127
70
508
Number of stitches with “thread clamp
closed” at end of seam*
Angle position for “thread clamp closed”
at end of seam
* Number of stitches (calculated back-
wards from the last stitch) till the thread
clamp is started. (
0
means last stitch)
0 - 3
0 - 127
0
80
510
Angle position for “thread clamp open”
at last needle penetration before trim-
ming
0 - 127
120
511
Securing stitches before thread trimming
0 - 2
0
512
Measuring point of the missed stitch de-
tection function with thread strength dis-
play
0 - 127
115
600
601
Move step motor clamp and needle