Adjustment
82
108-034
13
.23
Aligning the button clamp
Requirement
After selecting parameter "610", at the value "6" the needle should penetrate in the
centre of the opening in adjustment gauge
1
.
●
Switch on the machine and set parameter "112" at "off" (switch off stem finger).
●
Set parameter "610" at value "4" (open button clamp).
●
Using tweezers, insert adjustment gauge
1
(needle centre) and set parameter "610" at
value "5" (close button clamp).
●
Set parameter "610" at value "6" (lower button clamp).
●
Adjust button clamp
2
(screws
3
) in accordance with the
requirement
.
●
Connect the machine to the pneumatic system and check the setting again.
●
If necessary, correct the setting of button clamp
2
(screws
3
).
●
Set parameter "610" at value "1" and remove adjustment gauge
1
.
●
Switch off the machine and disconnect it from the pneumatic system.
The adjustment gauge 1 varies from button to button and can be ordered from
PFAFF (send button sample).
Fig. 13 - 21
2
3
1
3