113
Adjustment
Group
Parame-
ter
Description
Setting
range
Set
value
600
602
Inputs:
0123456789ABCDEF
Position on the Display
0: Not assigned
1: Not assigned
2: Nadel in den Stoff (NIS)
3: End knotting engaged
(E16 - X5:7)
4: Error reset key S101 (E12 - X5:12)
5: Not assigned (E11 – X5:11)
6: Loading control discharge station
B30 (E10 – X5:10)
7: Not assigned (E9 – X5:9)
8: Programmable input
1
(E8 – X5:16))
9: Programmable input
2
(E7 – X5:15)
A: Position clamp S26 (E6 – X5:14)
B: Not assigned (E5 – X5:5)
C: Clamp S24 (E4 – X5:4)
D: Position discharge station S23
(E3 – X5:3)
E: Reference needle (light barrier)
F: Reference clamp (light barrier)
▲
= Basic position
0
-
-
-
off
▲
off
▲
-
engaged
-
-
-
off
▲
-
raised
▲
off
▲
connected
connected
I
-
-
on
on
-
not
engaged
-
-
-
on
-
lowered
on
free
free
Meaning of the
display value