Adjustment
66
Fig. 13 - 06
1
2
2
3
5
4
6
1
To change the sensor board, it is imperative to observe the following work
steps!
Electric voltage!
Danger of an electric shock if handled incorrectly!
●
Completely remove the needle drive unit (plugs remain connected).
●
Loosen screws
2
.
13
.09
Sensor board of the needle drive
(in dismantled condition)
Requirement
1. When parameter "610" is set at "4", the recess in eccentric
1
should match the
locking hole in the mounting bracket.
2. The switch lug of eccentric
1
should be axially centred to the hybrid light barrier of
the sensor board.