PERMACONN AUST CONTACT ID EVENT TEMPLATE

 

Even

t ID

 

Part

 

Zone

 

Description

 

300

 

0

 

956

 

Panel Faulty - No activity detected from alarm panel 
indicating possible problem with panel.

 

 301

 

0

 

950

 

Mains Fail – No AC power available.

 

302

 

0

 

951

 

Battery Low – Battery voltage is low or absent.

 

313

 

0

 

953 & 

954

 

Engineering Reset (changed encryption key) – No  
action required.

 

337

 

0

 

950

 

Expansion Module DC Loss – 13.8V DC voltage low 
or absent.

 

338

 

0

 

951

 

Expansion Module Battery Fail – Battery voltage is 
low or absent.

 

350

 

0

 

953

 

Fail To Communicate – Permaconn experienced   
trouble sending signals do not expect restore.

 

351

 

0

 

954 & 

956

 

Phone Line Fail.

 

352

 

0

 

955 & 

956

 

Dialer

 

Interface Lead Fail – Issue with dialer

 

lead    

between Permaconn unit and the alarm panel.

 

353

 

0

 

956

 

Serial Interface Fail – Issue with Permaconn unit     
serial connection to the alarm panel.

 

356

 

0

 

968

 

IP path poll fail.

 

356

 

0

 

969

 

3G path poll fail.

 

356

 

0

 

970

 

Permaconn Outstation – Permaconn outstation is   
offline.

 

137

 

0

 

983

 

Tamper – Permaconn box tamper.

 

140

 

0

 

981

 

Auxiliary 1 – Auxiliary input on Permaconn unit.

 

140

 

0

 

982

 

Auxiliary 2 – Auxiliary input on Permaconn unit.

 

140

 

0

 

983

 

Auxiliary 3 – Auxiliary input on Permaconn unit.

 

140

 

0

 

984

 

Auxiliary 4 – Auxiliary input on Permaconn unit.

 

RDCCO_2143_E_IN 

PM1030 Manual March 2019 v2.2  

Содержание PM1030

Страница 1: ...PERMACONN PM1030 Includes DI300 Installation Manual RDCCO Pty Ltd Unit 3 9 11 Stubbs Street Rydalmere NSW 2116 Telephone 02 9352 1777 Web www permaconn com...

Страница 2: ...conn PM1030 7 DI300 Powered by Panel PM1030 Powered Independent Supply 7 PM1030 V2 and DI300 Powered by Panel Transmission Delay Times 8 LED Status Indicators PM1030 9 LED Status Indicators DI300 10 F...

Страница 3: ...to the registered fault recognition time Features of the Permaconn PM1030 Four 4 Inputs and a dedicated box tamper Three 3 Outputs Contact ID interface requires DI300 module RS485 RS232 Interface requ...

Страница 4: ...ogram alarm panel Generate an event from the alarm panel The Online GPOL LED will stay on steady Test all inputs and outputs Carry out all tests on Final Commissioning Check List Never leave site with...

Страница 5: ...he DI300 Connect PSTN in Mode 3 Unit is supplied as GPRS primary with PSTN back up To make the PSTN primary and GPRS back up the PSTN jumper must be re moved from the DI300 The option of PSTN primary...

Страница 6: ...one number Panel must report Contact ID format Panel must be programmed with a Hard ID Disable telephone line monitoring feature from the panel Battery Charging A dedicated 14 5V power supply is requi...

Страница 7: ...30 and the device being switched Tamper input does not require an EOL resistor All other inputs must be terminated with a 10K resistor Defaulting the Permaconn PM1030 Apply Battery or 14 5V DC power f...

Страница 8: ...ered by the alarm panel Transmission Delay Times Tamper input status message are transmitted immediately Message originating from the panel are forwarded immediately Alarm panel interface fail sent if...

Страница 9: ...LED Activity Indication POWER On Indicates battery or 14 5 Volt Power Off Indicates unit is off GSM On Unit not activated or network is not available Blinking 1 sec On 1 sec Off Searching for 3G netwo...

Страница 10: ...es fault with wiring between PM1030 and DI300 Check blue and white wire PSTN On Indicates that there is no line voltage on the incoming telephone from the ex change Off Indicates PSTN line voltage Off...

Страница 11: ...panel Verify with monitoring centre that correct CID account and event received Test alarm panel PSTN communication Remove jumper from DI300 Generate event from alarm panel Verify with monitoring cen...

Страница 12: ...mmunicate Permaconn experienced trouble sending signals do not expect restore 351 0 954 956 Phone Line Fail 352 0 955 956 Dialer Interface Lead Fail Issue with dialer lead between Permaconn unit and t...

Страница 13: ...rface Consult the relevant serial interface specifications Battery Low Fail DCV 11 8 Report delay 10 minute Restore DCV 12 5 Immediate Communications Class As per compliance statement Size 70 x 50 x 2...

Страница 14: ...e with AS 2201 5 Clause 3 9 on Subject to the Standard Terms and Conditions set out on the Activation Form for this unit INSTALLATION MUST BE CARRIED OUT BY SERVICE PERSONNEL ONLY CAUTION RISK OF EXPL...

Страница 15: ...15 NOTES RDCCO_2143_E_IN PM1030 Manual March 2019 v2 2...

Отзывы: